Overview :

Overview

For the temperature calibration professional that wants a highly accurate, easy-to-use, single function RTD temperature calibrator the Fluke 712B is the ideal test tool.

Product Highlights

  • The 712B can measure and simulate (13) different RTD types and resistance
  • Measure 4 to 20 mA signals while simultaneously sourcing a temperature signal
  • Hanging tool designed in and included with every unit
  • Configurable 0% and 100% source settings for quick 25% linearity checks
  • Linear ramp and 25% step auto ramp based on 0% and 100% settings
  • Dual inputs and backlit display for easy interpretation of measurements
  • Power down settings remembered at power up for easy restart of tests
  • 1-year and 2-year specifications and traceable certificate of calibration

Each Unit Includes

  • Magnetic Hanging Tool
  • Batteries
  • Manual
  • Traceable Calibration Certificate
  • Test Leads

Specifications :

General Specifications
Maximum voltage applied between any terminal and earth ground or between any two terminals 30 V
Operating temperature -10°C to 50°C
Storage temperature -30°C to 60°C
Operating altitude 2,000 m
Storage altitude 12,000 m
Relative humidity (% RH operating without condensation) Non condensing
90% (10°C to 30°C)
75% (30°C to 40°C)
45% (40°C to 50°C)
(Without condensation)
Vibration requirements MIL-T-28800E, Class 2
Drop text requirements 1 m
IP Rating IEC 60529: IP52
Electromagnetic environment IEC 61326-1, Portable
Safety IEC 61010-1, Max 30 V to earth, Pollution Degree 2
Power supply 4 AA NEDA 1.5A IEC LR6 batteries
Size (H x W x L) 52.5 x 84 x 188.5 mm
Weight 515 g
DC mA Measurement
Resolution 0-24 mA
Range 0.001 mA
Accuracy (% of reading + counts) 0.010% + 2 μA
Temperature coefficient ± (0.002% of reading + 0.002% of range) /°C ( < 18°C or >28°C)
Ohms Measurement
Ohms range Accuracy (% of reading +counts)
0.00 Ω to 400.00 Ω 0.015% + 0.05 Ω
400.0 Ω to 4000.0 Ω 0.015% + 0.5 Ω
Read accuracy is based on 4-wire input. For 3-wire ohm measurements, assuming all three leads are matched, add 0.05 Ω (0.00 Ω~400.00 Ω), 0.2 Ω (400.0 Ω~4000.0 Ω) to the specifications.
Temperature coefficient ±(0.002% of reading + 0.002% of range) / °C (< 18°C or > 28°C)
Ohms Source
Ohms range 1.0 Ω to 400.0 Ω
1.00 Ω to 400.00 Ω
400.0 Ω to 1500.0 Ω
1500.0 Ω to 4000.0 Ω
Excitation current from measurement device 0.1 mA to 0.5 mA
0.5 mA to 3 mA
0.05 mA to 0.8 mA
0.05 mA to 0.4 mA
Accuracy (% of reading + counts) 0.015% + 0.1 Ω
0.015% + 0.05 Ω
0.015% + 0.5 Ω
0.015% + 0.5 Ω
Resolution 0.00 Ω to 400.00 Ω 0.01 Ω
400.0 Ω to 4000.0 Ω 0.1 Ω
Temperature coefficient ± (0.002% of reading + 0.002% of range) /°C ( <18°C or >28°C)
Supports pulsed transmitters and PLCs with pulse times as short as 5 ms
RTD Input and Output
RTD Type (α) Range (°C) Measure (°C) Source (°C)
1-year 2-year Source current 1-year 2-year
10 Ω Pt (385) -200 to 100°C 1.5°C 3°C 1 mA 1.5°C 3°C
100 to 800°C 1.8°C 3.6°C 1 mA 1.8°C 3.6°C
50 Ω Pt (385) -200 to 100°C 0.4°C 0.7°C 1 mA 0.4°C 0.7°C
100 to 800°C 0.5°C 0.8°C 1 mA 0.5°C 0.8°C
100 Ω Pt (385) -200 to 100°C 0.2°C 0.4°C 1 mA 0.2°C 0.4°C
100 to 800°C 0.015%  0.03% 1 mA 0.02% 0.03%
+0.18°C +0.36°C +0.18°C +0.36°C
200 Ω Pt (385) -200 to 100°C 0.2°C 0.4°C 500 μA 0.2°C 0.4°C
100 to 630°C 0.02% 0.03% 500 μA 0.02% 0.03%
+0.18°C +0.36°C +0.18°C +0.36°C
500 Ω Pt (385) -200 to 100°C 0.3°C 0.6°C 250 μA 0.3°C 0.6°C
100 to 630°C 0.02% 0.03%  250 μA 0.02% 0.03% 
+0.28°C +0.56°C +0.28°C +0.56°C
1000 Ω Pt (385) -200 to 100°C 0.2°C 0.4°C 250 μA 0.2°C 0.4°C
100 to 630°C 0.02% 0.03% 250 μA 0.02% 0.03%
+0.18°C +0.36°C +0.18°C +0.36°C
100 Ω Pt (3916) -200 to 100°C 0.2°C 0.4°C 1 mA 0.2°C 0.4°C
100 to 630°C 0.02% 0.03% 1 mA 0.02% 0.03%
+0.18°C +0.36°C +0.18°C +0.36°C
100 Ω Pt (3926) -200 to 100°C 0.2°C 0.4°C 1 mA 0.2°C 0.4°C
100 to 630°C 0.02% 0.03% 1 mA 0.02% 0.03%
+0.18°C +0.36°C +0.18°C +0.36°C
10 Ω Cu (427) -100 to 260°C 1.5°C 3°C 1 mA 1.5°C 3°C
120 Ω Ni (672) -80 to 260°C 0.15°C 0.3°C 1 mA 0.15°C 0.3°C
50 Ω Cu (427) -180 to 200°C 0.4°C 0.7°C 1 mA 0.4°C 0.7°C
100 Ω Cu (427) -180 to 200°C 0.2°C 0.4°C 1 mA 0.2°C 0.4°C
YSI400 15 to 50°C 0.2°C 0.4°C 250 μA 0.2°C 0.4°C
1. Sensor inaccuracies not included.
2. Resolution: 0.1°C.
3. Read accuracy is based on 4-wire input. For 3-wire RTD measurements, assuming all three RTD leads are matched, add 1.0°C (Pt10 and Cu10), 0.6°C (Pt50 and Cu50), 0.4°C (Other RTD types) to the specifications.
4. Source Accuracy in source mode is based on 0.5 mA~3 mA (1.00 Ω~400.00 Ω), 0.05 mA~0.8 mA (400.0 Ω~1500.0 Ω), 0.05 mA~0.4 mA (1500.0 Ω ~4000.0 Ω), excitation current (0.25 mA for Pt1000 range).
5. Temperature Coefficient: ±0.05°C /°C for measure, ±0.05°C /°C (< 18°C or > 28°C) for source.
6. Supports pulsed transmitters and PLCs with pulse times as short as 5 ms.


Visit our Fluke Temperature Calibrator Selection Guide

Accessories :

Product Image MFG PART # PRODUCT DESCRIPTION Stock Status UNIT PRICE QTY
Fluke CXT80 CXT80 Rugged Pelican Hard Case In Stock

$199.99 USD

$177.79 USD

Fluke C25 C25 Soft Carrying Case for Fluke Meters In Stock

$39.99 USD

$35.55 USD

Fluke C550 C550 Premium Tool Bag In Stock

$99.99 USD

$88.89 USD

Fluke TLK-220 TLK-220 US SureGrip Accessory Set w/Meter Carrying Case In Stock

$149.99 USD

$133.34 USD

Fluke Free Tools Promo