The GX-3R is the worlds smallest 4 gas monitor weighing only 3.52 ounces and can comfortably be clipped within a worker’s breathing zone (2.2” W x 2.55” H x 1.02” D). It simultaneously monitors and displays LEL combustibles, O2, CO (Hydrogen compensated CO also available), and H2S.

OSHA defines the breathing zone as a ten inch radius around the worker’s nose and mouth, and requires that worker exposure monitoring air samples be collected in the breathing zone. Air sampling filters may be attached to the collar or lapel. Traditionally this means only a single gas monitor would be small enough for a worker to practically wear a gas monitor ‘In the breathing zone’. Now there is a 4 gas monitor smaller than many single gas monitors.
Product Highlights
- Smallest & lightest 4 gas monitor
- 2.2″ W x 2.55″ H x 1.02″ D, 3.52 ounces
- Simultaneous detection of 4 gases
- LEL, O2, H2S & CO
- H2 Compensated CO sensor available
- Simple 2-button operation
- Non-Compliance Indicator
- Alarms: audible, visual, & vibration
- 3 user adjustable alarm levels
- Impact resistant body with removable rubber boot
- Large LCD Auto-backlit display
- 25 hours of operation (Lithium-ion battery)
- Field replaceable sensors & filters
- Water and dust resistant design, IP66/68
- 3 Year warranty
Applications
- Personal monitoring
- Confined spaces
- Refineries/petrochemical
- Utilities
- Oil and Gas
- Water/Wastewater
- Fire Services
- Construction
Gas Detected |
(CO) |
Carbon Monoxide(CO) | Hydrogen Sulfide(H2S) | H2S Only |
Combustible Gases |
||
Dual Sensor |
|||||||
Sensor Slot |
1 |
2 | |||||
Detection |
EC | Dual EC | EC |
Catalytic combustion |
|||
Detection Range (Increments) |
0 ~ 2,000 ppm |
0 ~ 200.0 ppm (0.1 ppm) |
0 ~ 100% LEL |
||||
Accuracy Statement |
± 5% of reading |
± 5% of reading or ± 5 ppm CO (whichever is greater) |
± 5% of reading or ± 2 ppm H2S (whichever is greater) |
± 5% of reading |
|||
Sampling Method |
Diffusion sampling standard (hand aspirator or clip-on motorized pump optional) |
||||||
Display |
Digital LCD displays with 7 segment plus 14 segment plus icon |
||||||
Preset Alarms (User Adjustable) Overscale alarm (Non-adjustable) |
1st alarm: 25.0 ppm 2nd alarm: 50.0 ppm 3rd alarm: 1200.0 ppm TWA alarm: 25.0 ppm STEL alarm: 200.0 ppm Over alarm: 2000.0 ppm |
1st alarm: 5.0 ppm 2nd alarm: 30.0 ppm 3rd alarm: 100.0 ppm TWA alarm: 1.0 ppm STEL alarm: 5.0 ppm Over alarm: 200.0 ppm |
1st alarm: 10% LEL 2nd alarm: 25% LEL 3rd alarm: 50% LEL Over alarm: 100% LEL |
||||
Types of Alarms | Gas Alarm: 3 Increasing alarms, STEL, TWA, overscale alarm. O2 decreasing/increasing. Trouble alarm: Sensor disconnection, low battery, circuit error, calibration range error |
||||||
Display of Alarm | Gas Alarm: Flashing LEDs, continuous buzzer (100 db @ 30 cm), flashing gas value, vibration Trouble alarm: Flashing LEDs, intermittent buzzer (95 db @ 30 cm), display of error message |
||||||
Operating Temp. & Humidity |
-20°C ~ +50°C [ -4°F ~ +122°F ], 10 to 90% RH, non-condensing (continuous environment) -40°C ~ +60°C [ -40°F ~ +140°F ], 0 to 95% RH, non-condensing (temporary environment, 15 minutes) |
||||||
Response Time | Within 30 seconds (T90) | ||||||
Power Source | Lithium-ion battery, Approx. 25 hours after a 3 hour full charge | ||||||
Approvals | ATEX, CSA (Pending) | ||||||
Dimension & Weight |
2.2” W x 2.55” H x 1.02” D (Approx. 58 W x 65 H x 26 D mm), 3.52 ounces (approx. 100 g) without rubber booth 2.4” W x 2.63” H x 1.06” D (Approx. 61 W x 67 H x 27 D mm), 3.70 ounces (approx. 105 g) with rubber booth |
||||||
Case Material | Explosion proof, dust and water resistant to IP-66/68 (2m,1h) approval. Drop height 23 ft | ||||||
Controls | Two buttons: POWER / MODE, AIR | ||||||
Datalogging | Logs user ID, station ID, Calibration & Bump Test history, Alarm Events & Alarm Interval Trends | ||||||
Standard Accessories |
Alligator clip, protective rubber boot, charger, and calibration adapter | ||||||
Optional Accessories |
SDM-3R calibration station RP-3R Clip-on sampling pump with 4” rubber nipple, 10’ hose and probe (up to 40’ hose available) Padded carrying case for GX-3R and accessories USB to IrDA downloading cable for datalogger |
||||||
Warranty | Three years material and workmanship |
Related Products
-
Fluke Networks MT-8200-60-KIT IntelliTone Pro 200 LAN Toner & Probe Kit, SmartTone AnalogIntelliTone Pro 200 LAN Toner & Probe Kit, SmartTone AnalogAs low as $317.98
-
Fluke Networks 10210101 4-Wire In-Line Modular Adapter with K-Plug4-Wire In-Line Modular Adapter with K-PlugAs low as $49.04
-
Fluke Networks SMC-9-SCLCAPC-M Singlemode Launch Cable, 160M (SC/LCAPC), MetalSinglemode Launch Cable 160M (SC/LCAPC), MetalAs low as $363.40
-
Fluke Networks 52801004 TS52 Pro Test Set with 346A PlugTS52 Pro Test Set with 346A PlugAs low as $593.31
-
Fluke Networks 10200101 Spare Modular Adapter with K-Plug 4/6-Wire Cords, Five PackSpare Modular Adapter K-Plug 4/6-Wire Cords, Five PackAs low as $62.93
-
Fluke Networks LIQ-DUO-KIT-6PK Cable and Network Tester Kit Multi Pack of 6Cable and Network Tester Kit Multi Pack of 6As low as $19,246.49
-
Used Fluke Calibration 5616-12-P-USED Secondary PRT Probe, 1/4" x 12", 100 ohm
Secondary PRT Probe, 1/4" x 12", 100 ohm
As low as $724.52 -
Fluke Networks OFP-100-Q/GLD OptiFiber Pro 2 Quad OTDR, with WiFi & 1 Year Gold SupportOptiFiber Pro 2 Quad OTDR, w/ WiFi & 1 yr gold supportAs low as $18,003.43