Fluke Calibration 5616-12-P-USED Secondary PRT Probe, 1/4" x 12", 100 ohm

Secondary PRT Probe, 1/4" x 12", 100 ohm

Order #: 5616-12-P-USED

Mfg #: 5616-12-P-USED

Questions about availability or need help? Contact Us:

(800) 633-0561
$724.52

Fluke Calibration 5616-12-P-USED Secondary PRT Probe, 1/4" x 12", 100 ohm

Secondary PRT Probe, 1/4" x 12", 100 ohm

Order #: 5616-12-P-USED

Mfg #: 5616-12-P-USED

$724.52

Request a Used Instrument Quote

Have a Question? Speak to a Transcat Expert: 800.264.4059

Used instruments from TranscatTranscat Used Instrument Guarantee
Calibration Certificate Included 6 Month Warranty Unsurpassed Service & Support

Used instruments from TranscatTranscat is a Premier Supplier Used Test and Measurement Equipment. Many options are available for a variety of instruments. Contact Transcat for all your used equipment needs.

Availability: Call for Availability
This product is available for shipping to the United States, Canada, and Puerto Rico only.
This product is available for shipping to the United States, Canada, and Puerto Rico only.
This product is available for shipping to the United States, Canada, and Puerto Rico only.
This item is available as RENTAL at
Call for price
Shop now

Product Highlights

The temperature range of the 5616 covers -200 °C to 420 °C, and its high-purity platinum element and durability make it great for calibrating in the lab or in the field. When choosing a reference with a platinum element, there are two things you want to look at carefully: the short-term repeatability and the long-term drift. When PRTs are thermally cycled over their temperature range as they would be during a calibration, their resistance at the triple point of water can move up and down within an expected range. Fluke Calibration defines this range (called "short-term repeatability") as the repeatability at the triple point of water during three thermal cycles. 5616s are among the best performing in their class with short-term repeatability better than ± 0.010 °C (± 0.004 °C is typical). In addition, the 5616's drift is ± 0.007 °C at the triple point of water when exposed up to its maximum temperature (420 °C) for 100 hours. These specifications are given at k=2 and therefore include a 95 % confidence level.

  • Temperature range: -200 °C to 420 °C
  • Excellent stability: ± 10 mK
  • Reference-grade platinum sensing element
  • NIST-traceable calibration included
Win a Generac Generator when purchasing $750 or more from Transcat.Win a Generac Generator when purchasing $750 or more from Transcat.