0 Item(s)

Hioki RM3543-01

Resistance HiTester with GPIB

Order #: RM3543-01

Mfg Part #: RM3543-01

$4,950.00 USD

Usually ships in 7-10 days

Free shipping over $250

New Purchase Calibration Learn More

Save time and money by calibrating your new instrument before it leaves our warehouse, ensuring it arrives ready to be put into service. Find out how.

Add a Calibration to Your Item

Add Items to Cart

Request a Calibration Quote

Transcat can calibrate your existing instruments.

Request a Calibration Quote

Rent From Transcat

Do you need a test instrument for a short time?

Request a Rental Quote

click on image to view gallery image(s)

View All Hioki Products

Overview :

Product Highlights

  • ±0.16% accuracy & 0.01µohm resolution performance in automated systems
  • Superb repeatable measurement accuracy
  • Provide advanced contact-check, comparator, and data export functions
  • It is intuitive user interface and strong noise immunity are suitable for use in automated systems
  • Measurement method Four-terminal, constant-current DC
  • Resistance range 10 mohm (Max. 12.00000 mohm, 0.01 µohm resolution) to 1000 ohm range (Max. 1200.000 ohm, 1 mohm resolution), 7 steps
  • Display Monochrome graphic LCD 240 × 64 dot, white LED backlight
  • Measurement accuracy [at 10 mohm range, with SLOW mode, average 16 times settings]
  • ±0.060 % rdg. ±0.001 % f.s.
  • Testing current [at 10 mohm range] 1 A DC to [at 1000 ohm range] 1 mA DC
  • Open-terminal voltage 20 V DC max. Note: Voltage when not measuring is 20 mV or less, with current mode set at PULSE and Contact Improver Setting set at OFF/PULSE (measured with a voltmeter having 10 Mohm)
  • Sampling rate FAST, MEDIUM, SLOW, 3 settings
  • Integration time [at 10 mohm range, default value] FAST 2.0 ms, MED 5.0 ms, SLOW 1 PLC,
  • Setting range: 0.1 ms to 100.0 ms, or 1 to 5 PLC at 50 Hz, 1 to 6 PLC at 60 Hz
  • Note: PLC = one power line cycle (mains wave-form period)
  • Other functions Comparator (compare setting value with measurement value), Delay, OVC (offset voltage compensation), Average, Measurement fault detection, Probe short-circuit detection, Improve contact, Current mode setting (A pulse application function that applies current only during measurement), Auto-memory, Statistical calculations, Settings monitor (when using two instruments, a difference in settings causes warning notification), Retry, Trigger function. etc,.
  • Interface External I/O, RS-232C, Printer, GP-IB (Model RM3543-01)
  • External I/O Trigger, Hold input, Comparator output, Settings monitor terminal, Service power output +5V, +12V, etc.
  • Power supply, consumption 100 to 240 V AC, 50/60 Hz, 40 VA max.
  • Dimensions, mass 260 mm (10.24 in) W × 88 mm (3.46 in) H × 300 mm (11.81 in) D, 3.0 kg (105.8 oz)

Each Unit Includes

  • Power cord
  • EXT I/O male connector
  • Operation manual
  • Operation guide

Accessories :