0 Item(s)

Flowline LD32-S421

DeltaSpan, IS, Waste & oil, ETFE, 34.65 wc (15 psi)

Order #: LD32-S421

Mfg Part #: LD32-S421

$1,600.00 USD
 
 

This product is currently not available.

Request a Calibration Quote

Transcat can calibrate your existing instruments.

Request a Calibration Quote

Rent From Transcat

Do you need a test instrument for a short time?

Request a Rental Quote

click on image to view gallery image(s)

View All Flowline Products Discontinued Product

Overview :

Product Highlights

  • Corrosion resistant 316 SS transducer with ETFE cable, also available in polyurethane
  • Strong cable design with maintenance free breather tube and vent filter
  • Automatic temperature compensation
  • Rugged clog and damage resistant diaphragm design
  • Range: 0 to 10 psi (0.69 bar), 0 to 23' (0 to 10.4m) wc
  • Accuracy: ± 0.25% of full scale
  • Configuration: None, fixed span
  • Supply voltage: 10 to 28 VDC
  • Loop resist.: 900 Ohms
  • Signal output: 4-20 mA, two-wire
  • Process temp.: F: 0° to 176°/C: -18° to 80°
  • Temp. comp.: F: 0° to 176°/C: -18° to 80°
  • Proof pressure: 2 x full scale
  • Response time: 50ms
  • Weight: 4.3 lb (2.0 kg)
  • Trans. rating: NEMA 6 (IP67)
  • Trans. material: 316 SS, 316L SS, Buna-N
  • Trans. thread: 1/2" NPT
  • Cable type: 2-conductor, shielded with vent tube
  • Cable length: 40' (18.3m)
  • Cable material: ETFE (IS)
  • Classification: Intrinsically safe Class I Div. 1 Groups A, B, C & D; Class II Div. 1 Groups E, F & G; Class III Div. 1T4 @ 80 °C ambient
  • Compliance: CE, UL Intrinsically safe to UL standard 913 IEC 61000-4-2:2001 IEC 61000-4-3:2006 IEC 61000-4-4:2004 IEC 61000-4-5:2005 IEC 61000-4-6:2006 IEC 61000-4-8:2001 CENELEC EN 55011:2003 CENELEC EN 61326:2003 89/336/EEC EMC Directive
  • Parameters: Vmax = 28 VDC Imax = 93 mA Ci = 0.051_F Li = 240_H Pi = 0.651_W

Each Unit Includes

  • DeltaSpan Pressure Level Transmitter
  • Quickstart Guide

Accessories :