Order #: 65163MM
Mfg #: 2538815
Fluke 117
Order #: 65163MM
Mfg #: 2538815
Only need this item for a short time? Learn about rentals
Overview
Designed by Electricians. Engineered by Fluke - An Investment in Accuracy
With its integrated non-contact voltage detection and the AutoV/LoZ function preventing false readings caused by ghost voltage, the Fluke 117 Electrician's Multimeter is the ideal multimeter for electricians. In fact, users around the world have said their 117 is an investment in accuracy. The Fluke 117 provides Min/Max/Average readings, measuring frequency and capacitance. With its easy-to-use design, the Fluke 117 will save you time, allowing you to move from job to job with ease.
Engineered and Tested with Your Safety on the Job in Mind
We test our 117 Multimeters for safe use in CAT III 600 V environments. This is the ideal meter for your electrical work because:
- The large white LED backlight helps you work in poorly lit areas
- VoltAlertTM technology gives you fact, go/no go non-contact voltage detection
- AutoVolt and Low Input Impedance modes provide faster, more accurate readings
Product Highlights
- VoltAlert™ Technology for integrated non-contact voltage detection
- AutoVolt feature for automatic AC/DC voltage selection
- LoZ: low input impedance prevents false readings due to "ghost voltage"
- Large display and white LED backlight to work in poorly lit areas more effectively
- True-RMS for accurate measurements on non-linear loads
- Min/Max/Average to record signal fluctuations
- Compatible with optional magnetic hanger(ToolPak) for hands free operation
- Current measurement 20A(30 seconds momentary; 10A continuous)
- Resistance and continuity
- CAT III 600 V safety rated
- TL75 Hard Point Test Lead Set
Each Unit Includes
- TL75 Test leads
- Holster
- User manual
Webinars
Special Member Pricing
Buy with Calibration
Rental Instruments
Access to 100,000+ products
1,000's of instruments in stock
Product selection expertise
Application assistance
Purchase with a PO
- Fluke PRV240Battery-powered voltage source proving unit
Order #: PRV240
Mfg #: 4566209
Availability:In stockSpecial Price $164.25 Regular Price $190.99 - Fluke AC87Heavy Duty Bus Bar Clip Set
Order #: AC87
Mfg #: 1278079
Availability: Ships in 1-2 weeksSpecial Price $51.59 Regular Price $59.99 -
- Fluke TL220Industrial Test Lead Set for All Fluke Meters
Order #: TL20
Mfg #: 2003625
Availability:In stockSpecial Price $93.44 Regular Price $104.99 - Fluke 80PK-9Type K Lance Tip Probe, T/C Assembly,Moldd.Plug,1m,Bulk
Order #: 80PK-9
Mfg #: 1288229
Availability:In stockSpecial Price $88.99 Regular Price $99.99
Specifications | ||
Maximum voltage between any terminal and earth ground | 600 V | |
Surge protection | 6 kV peak per IEC 61010–1 600 VCAT III, Pollution Degree 2 | |
Fuse for A input | 11 A, 1000 V FAST Fuse (Fluke PN 803293) | |
Display | Digital: 6,000 counts, updates 4 per second | |
Bar graph | 33 segments, updates 32 per second | |
Operating temperature | -10°C to +50°C | |
Storage temperature | -40°C to +60°C | |
Battery type | 9 volt Alkaline, NEDA 1604A / IEC 6LR61 | |
Battery life | 400 hours typical, without backlight | |
Accuracy Specifications | ||
DC millivolts | Range/resolution | 600.0 mV / 0.1 mV |
Accuracy | ±([% of reading] + [counts]): 0.5% + 2 | |
DC volts | Range/resolution | 6.000 V / 0.001 V |
60.00 V / 0.01 V | ||
600.00 V / 0.1 V | ||
Accuracy | ±([% of reading] + [counts]): 0.5% + 2 | |
Auto volts | Range/resolution | 600.0 V / 0.1 V |
Accuracy | 2.0% + 3 (DC, 45 Hz to 500 Hz) | |
4.0% + 3 (500 Hz to 1 kHz) | ||
AC millivolts¹ True RMS | Range/resolution | 600.0 mV / 0.1 mV |
Accuracy | 1.0% + 3 (DC, 45 Hz to 500 Hz) | |
2.0% + 3 (500 Hz to 1 kHz) | ||
AC volts¹ True RMS | Range/resolution | 6.000 V / 0.001 V |
60.00 V / 0.01 V | ||
600.0 V / 0.1 V | ||
Accuracy | 1.0% + 3 (DC, 45 Hz to 500 Hz) | |
2.0% + 3 (500 Hz to 1 kHz) | ||
Continuity | Range/resolution | 600 Ω / 1 Ω |
Accuracy | Beeper on < 20 Ω, off > 250 Ω detects opens or shorts of | |
500 μs or longer. | ||
Ohms | Range/resolution | 600.0 Ω / 0.1 Ω |
6.000 kΩ / 0.001 kΩ | ||
60.00 kΩ / 0.01 kΩ | ||
600.0 kΩ / 0.1 kΩ | ||
6.000 MΩ / 0.001 MΩ | ||
Accuracy | 0.9% + 1 | |
Range/resolution | 40.00 MΩ / 0.01 MΩ | |
Accuracy | 5% + 2 | |
Diode test | Range/resolution | 2.00 V / 0.001 V |
Accuracy | 0.9% + 2 | |
Capacitance | Range/resolution | 1000 nF / 1 nF |
10.00 μF / 0.01 μF | ||
100.0 μF / 0.1 μF | ||
9999 μF / 1 μF | ||
100 μF to 1000 μF | ||
Accuracy | 1.9% + 2 | |
Range/resolution | > 1000 μF | |
Accuracy | 5% + 20% | |
Lo-Z capacitance | Range | 1 nF to 500 μF |
Accuracy | 10% + 2 typical | |
AC amps True RMS (45 Hz to 500 Hz) | Range/resolution | 6.000 A / 0.001 A |
10.00 A / 0.01 A | ||
Accuracy | 1.5% + 3 | |
20 A continuous overload for 30 seconds max | ||
DC amps | Range/resolution | 6.000 A / 0.001 A 10.00 A / 0.01 A |
Accuracy | 1.0% + 3 | |
20 A continuous overload for 30 seconds max | ||
Hz (V or A input)² | Range/resolution | 99.99 Hz / 0.01 Hz |
999.99 Hz / 0.1 Hz | ||
9.999 Hz / 0.001 Hz | ||
50.00 Hz / 0.01 Hz | ||
Accuracy | 0.1% + 2 | |
1. All AC voltage ranges except Auto-V/LoZ are specified from 1% to 100% of range. Auto-V/LoZ is specified from 0.0 V. | ||
2. Temperature uncertainty (accuracy) does not include the error of the thermocouple probe. | ||
2. Frequency is AC coupled, 5 Hz to 50 kHz for AC voltage. Frequency is DC coupled, 45 Hz to 5 kHz for AC current. | ||
2. Temperature Range/Resolution: -40°F to 752°F / 0.2°F. | ||
Mechanical and General Specifications | ||
Size | 167 x 84 x 46 mm (6.57 x 3.31 x 1.82 in) | |
Weight | 550 g | |
Warranty | 3 years |