With its simple operation, compact design and ease of use, the Fluke 115 True RMS digital multimeter provides the perfect answer for general purpose electrical and electronic test requirements. The Fluke 115 displays True RMS voltage and current readings with 600 count resolution, continuity and capacitance, making it perfect for quick verifications and field service use.
Fluke 115 Digital Multimeters are independently tested for safe use in CAT III 600V Environments.
Product Highlights
- Resistance, continuity, frequency, capacitance, and diode test
- Measures 10 A (20 A overload for 30 seconds)
- Large white LED backlight to work in poorly lit areas
- Compact ergonomic design for one-handed operation
- Compatible with optional magnetic hanger (ToolPak™)
- True-rms for accurate measurements on non-linear loads
- Min/Max/Average with elapsed time to record signal fluctuations
- CAT III 600 V safety rated
Each Unit Includes
- Holster
- Installed 9 V battery
- TL 75 Test leads
- User manual
Webinars
Special Member Pricing
Buy with Calibration
Rental Instruments
Access to 100,000+ products
1,000's of instruments in stock
Product selection expertise
Application assistance
Purchase with a PO
- Fluke TL220Industrial Test Lead Set for All Fluke Meters
Order #: TL20
Mfg #: 2003625
Availability:In stockSpecial Price $93.44 Regular Price $104.99 - Fluke PRV240Battery-powered voltage source proving unit
Order #: PRV240
Mfg #: 4566209
Availability:In stockSpecial Price $164.25 Regular Price $190.99 -
- Fluke 80PK-9Type K Lance Tip Probe, T/C Assembly,Moldd.Plug,1m,Bulk
Order #: 80PK-9
Mfg #: 1288229
Availability:In stockSpecial Price $88.99 Regular Price $99.99 - Fluke AC87Heavy Duty Bus Bar Clip Set
Order #: AC87
Mfg #: 1278079
Availability: Ships in 1-2 weeksSpecial Price $51.59 Regular Price $59.99
Specifications | ||
Maximum voltage between any terminal and earth ground | 600 V | |
Surge protection | 6 kV peak per IEC 61010–1 600 VCAT III, Pollution Degree 2 | |
Display | Digital: 6,000 counts, updates 4 per second | |
Bar graph | 33 segments, updates 32 per second | |
Operating temperature | -10°C to + 50°C | |
Storage temperature | -40°C to + 60°C | |
Battery type | 9 volt Alkaline, NEDA 1604A/ IEC 6LR61 | |
Battery life | 400 hours typical, without backlight | |
Accuracy Specifications | ||
DC millivolts | Range/resolution | 600.0 mV / 0.1 mV |
Accuracy | ± ([% of reading] + [counts]): 0.5% + 2 | |
DC volts | Range/resolution | 6.000 V / 0.001 V |
60.00 V / 0.01 V | ||
600.00 V / 0.1 V | ||
Accuracy | ± ([% of reading] + [counts]): 0.5% + 2 | |
AC millivolts1 True RMS | Range/resolution | 600.0 mV / 0.1 mV |
Accuracy | 1.0% + 3 (DC, 45 Hz to 500 Hz) | |
2.0% + 3 (500 Hz to 1 kHz) | ||
AC volts1 True RMS | Range/resolution | 6.000 V / 0.001 V |
60.00 V / 0.01 V | ||
600.0 V / 0.1 V | ||
Accuracy | 1.0% + 3 (DC, 45 Hz to 500 Hz) | |
2.0% + 3 (500 Hz to 1 kHz) | ||
Continuity | Range/resolution | 600 Ω / 1 Ω |
Accuracy | Beeper on < 20 Ω, off > 250 Ω detects opens or shorts of | |
500 μs or longer. | ||
Ohms | Range/resolution | 600.0 Ω / 0.1 Ω |
6.000 kΩ / 0.001 kΩ | ||
60.00 kΩ / 0.01 kΩ | ||
600.0 kΩ / 0.1 kΩ | ||
6.000 MΩ / 0.001 MΩ | ||
Accuracy | 0.9% + 1 | |
Range/resolution | 40.00 MΩ / 0.01 MΩ | |
Accuracy | 5% + 2 | |
Diode test | Range/resolution | 2.00 V / 0.001 V |
Accuracy | 0.9% + 2 | |
Capacitance | Range/resolution | 1000 nF / 1 nF |
10.00 μF / 0.01 μF | ||
100.0 μF / 0.1 μF | ||
9999 μF / 1 μF | ||
100 μF to 1000 μF | ||
Accuracy | 1.9% + 2 | |
Range/resolution | > 1000 μF | |
Accuracy | 5% + 20% | |
Lo-Z capacitance | Range | 1 nF to 500 μF |
Accuracy | 10% + 2 typical | |
AC amps True RMS | Range/resolution | 6.000 A / 0.001 A |
(45 Hz to 500Hz) | 10.00 A / 0.01 A | |
Accuracy | 1.5% + 3 | |
20 A overload for 30-seconds max | ||
DC amps | Range/resolution | 6.000 A / 0.001 A |
10.00 A / 0.01 A | ||
Accuracy | 1.0% + 3 | |
20 A overload for 30-seconds max | ||
Hz (V or A input)2 | Range/resolution | 99.99 Hz / 0.01 Hz |
999.9 Hz / 0.01 Hz | ||
9.999 kHz / 0.001 kHz | ||
50 kHz / 0.01 kHz | ||
Accuracy | 0.1% + 2 | |
1. All AC voltage ranges except Auto-V/LoZ are specified from 1% to 100% of range. Auto-V/LoZ is specified from 0.0 V. | ||
2. Frequency is AC coupled, 5Hz to 30 kHz for AC voltage. | ||
2. Temperature uncertainty (accuracy) does not include the error of the thermocouple probe. | ||
2. Frequency is AC coupled, 5 Hz to 50 kHz for AC voltage. Frequency is DC coupled, 45 Hz to 5 kHz for AC current. | ||
2. Temperature Range/Resolution: -40°F to 752°F / 0.2°F. | ||
Mechanical & General Specifications | ||
Size | 167 x 84 x 46 mm (6.57 x 3.31 x 1.82 in) | |
Weight | 550 g | |
Warranty | 3 years |