Order #: 773
Mfg #: 3362365
Fluke 773
Order #: 773
Mfg #: 3362365
The Fluke 773 milliamp clamp meter is accurate and versatile. It saves time and money by measuring 4–20 mA signals five times faster than with traditional DMMs, and without breaking the loop.
Fluke 773 Highlights
- Save over $190 with the Fluke 773 VIP Kit.
- Limited Time Offer.
- FREE Pelican 1450-C Hard case
- FREE Black and DC Voltage Detector
- FREE 6-50 VDC - Exclusively from Transcat
Fluke 773 Overview
Need more hours in your day?
Save time by NOT breaking the loop on 4-20 mA signal measurements.
Are you spending time:
- Taking mA measurements by removing a wire and breaking the loop
- Calling the control room to isolate a loop
- Testing analog input/output on a console
- Troubleshooting devices with mA inputs and outputs
- Repairing intermittent or erratic 4-20 mA loops
- Going back to the shop to get extra tools
If you need more time in your busy day take a good look at the Fluke 773 mA Clamp Meters. It's designed to save you time, and money, by eliminating time wasting activities. Now you can troubleshoot and repair 4-20 mA loops without breaking the loop or bringing down the system.
Fluke 773 Features
- Best in class 0.2 % accuracy
- 0.01 mA resolution and sensitivity
- Measure 4 to 20 mA signals without "breaking the loop"
- Measure mA signals for PLC and control system analog I/O
- Dual backlit display with both mA measurement and percent of 4 to 20 mA span
- Measurement Spotlight illuminates hard to see wires in dark enclosures
- Detachable clamp with extension cable for measurements in tight locations
- Measure 10 to 50 mA signals in older control systems using the 99.9 mA range
- Automatically change the 4 to 20 mA output for remote testing
- Power saving features, auto-off, backlight timeout extend battery life
- Hold function captures and displays changing measurements
- Measure 4 to 20 mA signals with in-circuit measurement
- Simultaneous mA in-circuit measurement with 24V loop power for powering and testing transmitters
- Source 4 to 20 mA signals for testing control system I/O or I/Ps
- mA output linear ramp or 25% step output
- DC voltage measurement to verify 24V power supplies or voltage I/O signals
- Source DC voltage to test input devices that accept a 1-5V or 0 to 10V signals
- Scaled mA output provides a continuous mA signal that corresponds to the 4 to 20 mA signal measured by the mA clamp
- mA in/out: simultaneously measure the mA signal with the clamp and source a mA signal
- Voltage output linear ramp or 25% step output
Each Fluke 773 Includes
- Four AA alkaline batteries (installed)
- Soft carrying case
- TL75 test leads
- AC 72 detachable clip
- TL 940 mini hook test leads
- Instruction sheet
- Hanging tool with hook and loop strap
Webinars
Special Member Pricing
Buy with Calibration
Rental Instruments
Access to 100,000+ products
1,000's of instruments in stock
Product selection expertise
Application assistance
Purchase with a PO
-
- Fluke PRV240Battery-powered voltage source proving unit
Order #: PRV240
Mfg #: 4566209
Availability:In stock$177.99 - Transcat 5353C-GCalibration Labels-Green, Self-Laminating, 1 3/4x5/8"
Order #: 5353C-G
Mfg #: CUSTOM QCC306-GR (QZ0530GR)
Availability:In stockSpecial Price $22.94 Regular Price $24.15
- Fluke 787BProcessMeter, TRMS DMM & mA loop calibrator
Order #: 787B
Mfg #: 4777186
Availability:In stock$1,153.99
Specifications | ||
Diameter of measurable conductor | 0.177" or 4.5 mm max | |
Operating temperature | -10 to 50ºC | |
Storage temperature | -25 to 60ºC | |
Operating humidity | < 90% @ <30ºC, < 75% @ 30 to 55ºC | |
Operating altitude | 0 to 2000 m | |
IP rating | IP 40 | |
Size | 44 x 70 x 246 mm (2 7/8 x 5 ¾ x 11 5/8 in) | |
Weight | 410 g, (14.4 oz) | |
Vibration | Random 2 g, 5 to 500 Hz | |
Shock | 1 meter drop test (except the jaw) | |
EMI/RFI | Meets EN61326-1 | |
For current measurement w/ JAW, add 1mA to specification for EMC field strengths of 1V/m up to 3V/m. | ||
Temperature coefficient | 0.01% ºC | |
(< 18ºC or > 28ºC) | ||
Power, battery life | (4) AA 1.5 V Alkaline, IEC LR6, 12 hours in mA source into 500 ohms | |
Warranty | Three years for electronics | |
One year for cable and clamp assembly | ||
Functional Specifications | ||
mA measurement | Resolution / range | 0 to 20.99 mA |
(measured by clamp) | Accuracy | 0.2% + 2 counts |
Resolution / range | 21.0mA to 100.0 mA | |
Accuracy | 1% + 5 counts | |
mA measurement (measured in series with test jacks) | Resolution / range | 0 to 24.00 mA |
Accuracy | 0.2% + 2 counts | |
mA source (maximum mA drive: 24 mA into 1,000 ohms) | Resolution / range | 0 to 24.00 mA |
Accuracy | 0.2% + 2 counts | |
mA simulate (maximum voltage 50 V dc) | Resolution / range | 0 to 24.00 mA |
Accuracy | 0.2% + 2 counts | |
Voltage source (2 mA maximum drive current) | Resolution / range | 0 to 10.00 V DC |
Accuracy | 0.2% + 2 counts | |
Voltage measure | Resolution / range | 0 to 30.00 V DC |
Accuracy | 0.2% + 2 counts |