Additel AM1710-BEND-ADT-17025 100Ohm Secondary PRT, -40 to 160C, 1/4", 90deg Bend at 7.5

Additel AM1710-BEND-ADT-17025 100Ohm Secondary PRT, -40 to 160C, 1/4", 90deg Bend

Order # AM1710-BEND-ADT-17025

Mfg # AM1710-BEND-ADT

call-regular 800-828-1470
$1,368.00
Loading...
Loading...
  • Overview
  • Technical Resources
  • Specifications
  • Used With

Additel AM1710-BEND-ADT-17025 100Ohm Secondary PRT, -40 to 160C, 1/4", 90deg Bend

Order # AM1710-BEND-ADT-17025 | Mfg # AM1710-BEND-ADT
$1,368.00
arrow_drop_down

Tariff fees or manufacture imposed surcharges may be applicable.

This product is available for shipping to the United States, Canada, and Puerto Rico only.

Overview

Product Highlights

100 Ohm Secondary PRT, -40 to 160°C, 1/4", 90° Bend at 7.5" from tip, with Lemo smart connector, 2 m cable length, including accredited calibration.

  • Temperature Range: -40°C to 160°C
  • Accuracy: <0.012°C at 0.01°C
  • Long Term Drift: <0.01°C
  • Short-term Stability: <0.007°C
  • Durable and Shock Resistant
  • Temperature Coefficient 0.003925Ω/ Ω/ °C
  • Fully Meets the ITS-90 Criteria for Reference Thermometers
  • Stainless Steel Sheath

The AM1710 series of Secondary Reference PRTs offers affordable reference probes for precision temperature measurement and calibration both in the lab and in the field. These PRTs feature an accuracy of <0.012°C and a short term stability of <0.007°C. To reach the best performance in stability and repeatability, the sensing element has been specially designed to protect the platinum sensing wire from contamination at high temperatures. A unique supporting structure and filling material provide the best balance among the hysteresis effect, mechanical shock and thermal shock performance. This high performance probe fully meets the ITS-90 criteria for reference thermometers. Each probe comes standard with an NIST-traceable certificate of calibration.

Technical Resources

Specifications

1710-12 1710-BEND
Temperature Range -40°C to 160°C
Nominal Resistance at 0.01°C 100 Ω
Temperature Coefficient 0.003925 Ω/Ω/°C
Accuracy <0.012°C at 0.01°C
Long Term Drift at 0.01°C <0.01°C at TPW after 100 hours at 160°C
Short Term Stability <0.007°C
Thermal Shock <0.005°C after 10 thermal cycles from minimum to maximum temperatures
Hysteresis ≤0.005°C
Self-heating 50 mW/°C
Response Time 9 seconds
Sheath Length 12 in (305 mm); 7 in (178 mm) from tip to bend 4 in (101.6 mm) from bend to handle
Sheath Diameter 0.25 in (6.35 mm)
Sensor Element Length 1.26 in (32 mm)
Sensor Element Location 0.12 in (3 mm) from tip
Insulation Resistance >1000 MΩ at room temperature
Sheath Material Stainless steel
External Leads Teflon™ insulated copper wire, 4 leads, 6.5 feet (2 meters)
Handle Dimension 0.59 in (15 mm) (OD) x 2.56 in (65 mm) (L) 0.59 in (15 mm) (OD) x 2.56 in (65 mm) (L)
Handle Temperature Range -40°C to 160°C
Calibration NIST-traceable calibration with data