Fluke Calibration 5615-12-B Secondary PRT Probe, 100 ohm, 1/4 x 12"
Secondary PRT Probe, 100 ohm 1/4 x 12"

Order #: 5615-12-B

Mfg #: 3002831

Questions about availability or need help? Contact Us:

(800) 633-0561
$1,740.00

Fluke Calibration 5615-12-B Secondary PRT Probe, 100 ohm, 1/4 x 12"

Secondary PRT Probe, 100 ohm 1/4 x 12"

Order #: 5615-12-B

Mfg #: 3002831

$1,740.00
Availability: Ships in 3-4 weeks

Choose Your Options:

Tariff fees or manufacture imposed surcharges may be applicable.
This product is available for shipping to the United States, Canada, and Puerto Rico only.

Product Highlights

  • Secondary Standard PRT
  • 6.35 mm x 305 mm (0.250 x 12.0 in)
  • -200 to 420 °C
  • For years, you've relied on our 5612, 5613, and 5614 Secondary Reference Probes
  • These field-durable, lab-accurate PRTs have been replaced by the 5615, which comes with a accredited calibration
  • The 5615-12 is a Platinum Resistance Thermometer (PRT) with an Inconel™ 600 sheath that's 305 mm (12 in) long and 6.35 mm (0.250 in) in diameter
  • It is a secondary reference temperature standard designed to bridge the gap between the highest laboratory standards and industrial or second-tier lab locations
  • It has short-term accuracy of ±0.013 °C at 0.01 °C
  • The element is constructed of reference-grade platinum wire (99.999 % pure) for excellent stability
  • The wire is wound in a coil and placed in a mandrel where it's uniformly supported in a manner that virtually eliminates hysteresis
  • The electrical configuration is a four-wire current-potential hookup that eliminate the effects of lead-wire resistance
  • These Inconel™-sheathed probes have a fully supported sensing element, making them more durable than SPRTs
  • The element is protected in an ultrahigh-purity ceramic case with a hermetic glass seal to improve output stability by locking out moisture and contaminants
  • This probe comes calibrated with ITS-90 coefficients, making it compatible with many excellent readout devices, including Hart's 1529 Chub-E4, 1560 Black Stack, and 1502A Tweener
  • It bridges the gap between a 100-ohm industrial RTD and an SPRT
  • For those needing faster thermal response, or where diameter and immersion depth are problems, order the 5615-9 or 5615-6
  • These probes are excellent reference probes for comparison calibrations in a Hart dry-well
  • The sheaths of the 5615-6 and 5615-9 are 4.76 mm (0.188 in) in diameter
  • A printout of sensor resistance is provided in 1 °C increments for each probe
  • The 5615-9 and 5615-12 are calibrated from -196 °C to 420 °C (The 5615-6 is calibrated to 300 °C)

Each Unit Includes

  • Accredited Calibration