The Testo 190T1 (0572 1901) 1-Channel CFR System Temperature Data Logger is ideal for efficient monitoring of sterilization processes. Designed for pharmaceutical industry applications, the 190-T1 features a short and rigid temperature probe that is particularly small and ideal for temperature monitoring within confined spaces over the -58°F to 284°F (-50°C to 140°C) range.
The 190-T1 model is part of the highly efficient and reliable data logger system suited for validation of controlled temperature units, sterilization, and freeze-drying processes that comprises of the data logger itself and the 190 system software. The 0554 1901 CFR Software (sold separately) is required for the wireless configuration and read out of the data logger when enclosed in the 0516 1901 Small Transport Case (sold separately) that features an integrated programming and readout unit. This complete system provides users with effective support in monitoring processes and quality parameters to ensure the correct functioning of all processing systems while meeting all regulatory requirements regarding documentation. One-click reporting within the software means that 21 CFR part 11 compliant documentation can be easily achieved.
- Requires 0516 1901 Small Transport Case and 0554 1901 CFR Software for programming and readout
- 0516 1901 Small Transport Case doubles as storage/transport case and readout unit
- 0554 1901 CFR Software allows users to program or read out data logger and analyze measurement data on PCs
- Designed for pharmaceutical industry applications, accurately monitors temperature
- Ideal for efficient monitoring of sterilization processes
- Fitted with short/rigid temperature probe that is suited for temperature monitoring within confined spaces
- Small and slim design for use within tight objects or cramped conditions
- Threading offers easy securing option and practical solution for attachment of 0554 0297 Retaining Clamps
- Robust and durable construction with hermetically sealed measuring technology in separate stainless steel housing
- Battery and measuring technology are contained in two separate housings
- Battery can be changed quickly and securely without requiring additional tools or lubricants
- Instrument remains 100% tight even after batteries are changed
- Battery housing is coated in high-temperature-resistance polyether ether ketone (PEEK) resilient plastic
- Flexible height via adaptation of two separate battery sizes, large or small
Applications
- Sterilization Processes
- Freeze-Drying
- Controlled Temperature Units
- Confined Spaces
Each Unit Includes
- 1 - 190-T1 1-Channel CFR System Temperature Data Logger with 1x Short/Rigid Probe, -58°F to 284°F (0572 1901)
- 1 - Long Distance Adapter (0554 0299)
- 1 - 1/2 AA Lithium Large Battery, 3.6V, 800 mAh, -58°F to 284°F (0515 1901)
- 1 - Calibration Protocol
- 1 - User Manual