Already have this this item and need calibration? Request a calibration quote

Input Signals

  • 4-20 mA DC (z in 10 ohms)
  • 0-20 or ± 20 mA DC (z in 10 ohms)
  • 0-10 or ±10 mA DC (z in 20 ohms)
  • 0-1 or ±1 mA DC (z in 200 ohms)
  • 1-5 VDC (z in 1 megohm)
  • 0-5 or ±VDC (z in 1 megohm)
  • 0-10 or ±10 VDC (z in 1 megohm)
  • Any unipolar or bipolar voltage from 100 MV to 200 VDC. (Option I 14)
  • Zero Suppression: ±10%
  • Span Adjustment: ±10%

Performance

  • Calibrated Accuracy: ±0.1%
  • Independent Linearity: ±0.025% maximum, ±0.01% typical
  • Repeatability: ±0.005% max., ±0.002% typ.
  • Zero TC: ±0.007% of span max./°C
  • Span TC: ±0.008% of span max. / °C
  • Load Effect: ±0.005% zero to full load
  • Output Ripple: 10 mV P/P maximum
  • Response Time: 110 milliseconds ( 10 to 90% step response)
  • Bandwidth: (-3 db): 3.2 Hz
  • Temperature Range: -25° to 185°F (-31° to 85°C) operating; -40° to 200°F (-40° to 93°C) storage
  • Power Supply Effect: ±0.005% over operating Range
  • Isolation: Input/output/case: 1000 VDC, 600 VAC

Power:

  • 8 to 42 VDC: Standard

Ordering Options:

  • H 15 D, H 25 - H 30 Mounting
  • LPI 40 D Loop powered indicator
  • I 14 Voltage / current inputs