Product Highlights

The Solmetric line of PV Analyzer I-V curve tracers are widely used in Commissioning, Auditing, O&M, and Troubleshooting of PV systems.

The PVA-1500 kit offers an array of advanced features, including high throughput I-V curve tracing, providing quick and detailed performance data. Its intuitive user interface enables easy navigation and real-time analysis, allowing for immediate identification of potential issues. By pinpointing problems early, you can maximize your solar energy production and minimize downtime.

This toolkit combines the precision of the Fluke Solmetric PVA-1500HE2 I-V Curve Tracer, the versatility of the Fluke 393 FC Solar Clamp Meter, the reliability of the Fluke 87V Digital Multimeter, and the advanced capabilities of the Fluke 1587 FC Insulation Multimeter. The PVA-1500HE2 offers an array of advanced features, including high throughput I-V curve tracing, providing quick and detailed performance data. Its intuitive user interface enables easy navigation and real-time analysis, allowing for immediate identification of potential issues. The 393 FC Solar Clamp Meter enables precise measurement of DC current and voltage, essential for performance testing and troubleshooting of solar panels and inverters. The 87V Digital Multimeter provides reliable measurements of AC/DC voltage, current, resistance, and capacitance, facilitating system integrity verification and electrical fault diagnosis. Additionally, the 1587 FC Insulation Multimeter offers insulation resistance testing, helping to identify potential safety hazards and prevent system failures. From commissioning and routine maintenance to troubleshooting and performance optimization, this toolkit empowers solar professionals to ensure the efficiency, reliability, and safety of solar installations with confidence.

  • Comprehensive toolkit: This kit combines the precision of the Fluke Solmetric PVA-1500HE2 I-V Curve Tracer, the versatility of the Fluke 393 FC Solar Clamp Meter, the reliability of the Fluke 87V Digital Multimeter, and the advanced capabilities of the Fluke 1587 FC Insulation Multimeter, offering a complete solution for solar installation diagnostics and maintenance.
  • Advanced I-V curve tracing: The PVA-1500HE2 provides high throughput I-V curve tracing, delivering quick and detailed performance data for efficient diagnostics and maintenance.
  • Precise measurement capabilities: The 393 FC 1500V Solar Clamp Meter ensures precise measurement of DC current and voltage, while the 87V Digital Multimeter offers reliable measurements of AC/DC voltage, current, resistance, and capacitance, essential for system integrity verification and electrical fault diagnosis.
  • Safety enhancement: The 1587 FC Insulation Multimeter offers insulation resistance testing, aiding in identifying potential safety hazards and preventing system failures, ensuring the safety and reliability of solar installations with confidence.
  • Key Attributes

    • DC Voltage: 1500V
    • Current: 30A DC (Module Efficiency <19%)
    • Current: 30A DC (Module Efficiency ≥19%)
    • Accessories Included: PVA-1500HE2: PVA HE2 unit, transit case, SolSensor™ and clamp, Windows application, alligator test leads, MC4 disconnect tool, chargers, Data Analysis Tool (DAT), 2x thermocouples and adhesive disks, sensor cleaning supplies
      • 393 FC: Fluke 393 FC CAT III 1500 V TRMS clamp meter, Test leads (CAT III 1500 V rated, right angle plugs, with safety caps), iFlex 18 inch flexible current probe, TPAK magnetic hanging strap, Premium carrying case
      • 87V: Fluke 87V MAX True-rms Digital Multimeter, TL175 TwistGuard® test leads, AC175 Alligator clips, 80BK-A temperature probe, Removable holster with test lead storage, Three AA batteries (installed)
      • 1587 FC: Fluke 1587 FC Insulation Multimeter, Remote probe, Test leads, Alligator clips, K-type thermocouple, Soft case

    Features

    • Best accuracy
    • High Efficiency
    • Highest measurement throughput (# I-V measurements per hour)
    • Solmetric + 1587FC+393+87V
    • Largest display with best array troubleshooting features
    • Database of 70,000 PV modules
    • Measures up to 1500V at 30A
    • 300 foot wireless sensor range

    393 Features

    • DC Voltage: 1500 V, 1% accuracy
    • CAT III: 1500 V
    • DC Power: 1500 kVA, 2% accuracy
    • AC Current: Jaw: 1000 A, 2% accuracy

    87V Features

    • Unique function for accurate voltage and frequency measurements on adjustable speed True-rms ac voltage and current for accurate measurements on non linear signals
    • Built in thermometer conveniently allows you to take temperature readings without having to carry a separate instrument
    • Motor drives and other electrically noisy equipment
    • Measure up to 1000 V ac and dc
    • Measure up to 10 A (20 A for 30 seconds)
    • 10,000 uF capacitance range
    • Frequency to 200 kHz and % duty cycle
    • Peak capture to record transients as fast as 250 uS with Peak Capture

    1587 FC Features

    • Pi/DAR timed ratio tests with TrendIt graphs identifies problems faster
    • Memory storage through Fluke Connect eliminates writing down results, reduces errors and saves data for historical tracking over time
    • Temperature Compensation for establishing accurate baselines and relevant historical comparisons
    • Live circuit detection prevents insulation test if voltage > 30 V is detected for added user protection
    • VFD low-pass filter for accurate motor drive measurements
    • Auto-discharge of capacitive voltage for added user protection