The Instek GDP-040D Dual-Channel Differential Probe is an accessory for use with the GDS-200/300 Series Handheld Oscilloscopes. To use the differential probe on the GDS-200/300, simply set the probe attenuation to x200. It can achieve isolated results for measurements with strict power and grounding requirements.
Type: Dual-Channel Differential Probe
Number of Channels: 2
Bandwidth (-3dB): DC-40MHz (x200)
Attenuation: x200
Accuracy: +/- 2%
Voltage Input Range: 600Vrms for x200
Input Impedance:
Differential: 2MOhm//1.2pF
Between Terminal and GND: 1MOhm//2.4pF
Output: ≤+/-3V
Output Impedance: 50Ohm
Rise Time: 8.75ns for x200
CMRR: 80dB at 60Hz, 60dB at 100Hz, 50dB at 1MHz
Power Supply: 5V DC from GDS-200