This model measures temperature in air, water, or soil. Accuracy and resolution vary according with attached logger model. Measurement range is -40° to 50°C (-40° to 122°F) in water or soil, -40° to 100°C (-40° to 212°F) in air; response time is minutes typical to 90% in air moving 1 m/sec (2.2 mph); response time in stirred water is 1 minute typical to 90%. This model sensor is attached to a 1.8m (6ft) cable.
Plug directly into the external input jacks of U12, UX120, or ZW Family loggers to expand the range of measurement options and applications
This sensor operates in indoor, outdoor and underwater environments.
The TMC6-HD sensor supports the following measurements: Temperature and Water Temp
Measurement range: -40° to 50°C (-40° to 122°F) in water; -40° to 100°C (-40° to 212°F) in air
Accuracy:
w/U12: ±0.25°C from 0° to 50°C (±0.45°F from 32° to 122°F), insert probe 2.3 cm (0.9 inches) minimum;
w/ZW: ±0.21°C from 0° to 50°C (±0.38°F from 32° to 122°F), insert probe 2.3 cm (0.9 inches) minimum;
w/UX120-006M: ±0.15°C from 0° to 70°C (±0.27°F from 32° to 158°F), insert probe 2.3 cm (0.9 inches) minimum;
Resolution:
w/U12: 0.03° at 20°C (0.05° at 68°F);
w/ZW: 0.02°C at 25°C (0.04°F at 77°F);
w/UX120-006M: 0.002° at 25°C (0.003° at 77°F);
Drift: <0.1°C (<0.2°F) per year
Response time in air: 2 min. typical to 90% in air moving 1 m/sec (2.2 mph)
Response time in stirred water: 30 sec. typical to 90%.
Operating range: Sensor tip and cable immersion in fresh water up to +50°C (122°F) for 1 year