NH Research CAL300 for Rent, Calibrator for NH Research 4700, 4760, 4730, 9200/9300, 9401

NH Research CAL300 for Rent, Calibrator for NH Research 4700, 4760, 4730, 9200/9300, 9401

Order # CAL300-RENT2

Mfg # CAL300-RENT2

call-regular 800-828-1470
$0.00
  • Overview
  • Technical Resources
  • Accessories

NH Research CAL300 for Rent, Calibrator for NH Research 4700, 4760, 4730, 9200/9300, 9401

Order # CAL300-RENT2 | Mfg # CAL300-RENT2

Request a Rental Quote

Have a Question? Speak to a Transcat Rental Expert: 800.264.4059

Have a Question?

Speak to a Transcat Rental Expert at 800.264.4059

Tariff fees or manufacture imposed surcharges may be applicable.

This product is available for shipping to the United States, Canada, and Puerto Rico only.
Loading...

NH Research CAL300 for Rent, Calibrator for NH Research 4700, 4760, 4730, 9200/9300, 9401 Accessories

checkbox-empty
checkbox-checked
NH Research CAL300CBL-94 for Rent, CAL300 Calibration Cable for 94XX DC Loads
checkbox-empty
checkbox-checked
NH Research CAL300CBL-93 for Rent, Calibration Cable for 9300/9200 Battery Testers
checkbox-empty
checkbox-checked
NH Research CAL300CBL-4912 for Rent, CAL300 Calibration Cable for 4912 Series
checkbox-empty
checkbox-checked
NH Research CAL300CBL-4960 for Rent, CAL300 Calibration Cable for 4960 Series
checkbox-empty
checkbox-checked
NH Research CAL300CBL-4700 for Rent, CAL300 Calibration Cable for 4700 Series
checkbox-empty
checkbox-checked
NH Research CAL300CBL-4760 for Rent, CAL300 Calibration Cable for 4760 Series
Total:

Overview

Product Highlights

  • Automatic calibration without special skills
  • Relatively low equipment costs
  • Straight forward setup with cables provided
  • Very low current (Energy Star) calibration capability
  • PC control through LAN with SCPI & VXl-11 communications

Application

The CAL300 Calibrator is designed to be used with a user-provided 81/2 Digit DMM (Agilent/Keysight 3458A or equivalent) plus supplemental DC Sources or Power Resistor Box depending on the specific product family to be calibrated. Calibration software that includes full instructions on connection and use has already been provided in the Software Package that accompanied the original product.

Ease of Use & Rapid Results

A graphical, interactive application makes calibration a straightforward process capable of being performed by a technician or engineer without calibration expertise in 2 to 3 hours. At the conclusion of the calibration the user then saves the calibration data to a flash drive or a file.

Additional Instruments Required

Given the wide assortment of NHR products that the CAL300 covers, some additional instruments are necessary for specific product families. To calibrate the 4700, 4760 and 4300 DC Loads, high & low-voltage DC sources are required. To calibrate the 9200/9300 Battery Test Systems, a NHR Resistive Load Box is required.

Technical Resources