Order #: HDO6104-MS-USED
Mfg #: HDO6104-MS-USED
Used Lecroy HDO6104-MS HD Mixed Signal Oscilloscope, 2.5Gs /s, 1GHz, 4+16 Channel, 50Mpts/Channel
Order #: HDO6104-MS-USED
Mfg #: HDO6104-MS-USED
Product Highlights
- 350 MHz, 500 MHz and 1 GHz bandwidths
- Long Memory - up to 250 Mpts/Ch
- Spectrum Analyzer Mode
- WaveScan - Advanced Search and Find
- History Mode - Waveform Playback
- Power Analysis Software
- JITKIT Clock-Data Jitter Analysis
- Serial Data Trigger and Decode
- PROTObus MAG Serial Data Debug Toolkit
- LabNotebook Report Generation
- Advanced Trigger Tools including TriggerScan
- 16 Digital Channels with 1.25 GS/s Sample Rate
- 12-bit ADC resolution, up to 15 bits with enhanced resolution
Combining Teledyne LeCroy's HD4096 high definition 12-bit technology, with long memory, a compact form factor, 12.1" touch screen display, powerful measurement and analysis tools, and mixed signal capability, the HDO6000 is the ideal oscilloscope for circuit validation, system debug and waveform analysis. The powerful feature set provides analytical tools and unique application packages to streamline the testing process. Tools such as WaveScan Search and Find and History Mode, combined with advanced triggering, identify and isolate problems while Spectrum Analyzer Mode provides analysis tools in the frequency domain.
HD4096 Technology
HD4096 high definition technology consists of high sample rate 12-bit ADCs, high signal-to-noise input amplifiers and a low-noise system architecture. This technology enables high definition oscilloscopes to capture and display signals of up to 1 GHz with high sample rate and 16 times more resolution than other oscilloscopes.
Long Memory
With up to 250 Mpts of memory the HDO6000 High Definition Oscilloscopes can capture large amounts of data with more precision than other oscilloscopes. The 2.5 GS/s, 250 Mpts architecture provides the ability to capture a fast transient or a long acquisition.
Large 12.1" Touch Screen
Navigating complicated user interfaces is a thing of the past thanks to the large touch screen display of the HDO6000. The user interface was designed for touch screens which makes navigating the HDO6000 extremely intuitive.
Comprehensive Analysis Tools
Advanced math and measurement parameters quantify andlog and digital waveforms while tracks, trends and histograms show how they change over time. Advanced triggering with TriggerScan and Measurement Trigger ensure even the most complicated signals are captured.
Analog - Vertical | |
---|---|
Bandwidth @ 50 Ω (-3 dB) | 1 GHz |
Rise Time (10-90%, 50 Ω) | 450 ps typical |
Input Channels | 4 |
Vertical Resolution | 12-bits; up to 15-bits with enhanced resolution (ERES) |
Sensitivity | 50 Ω: 1 mV/div-1 V/div, fully variable 1 MΩ: 1 mV/div-10 V/div, fully variable |
DC Gain Accuracy (Gain Component of DC Accuracy) | ±(0.5%) F.S, offset at 0 V |
Bandwidth Limiters | 20 MHz, 200 MHz |
Maximum Input Voltage | 50 Ω: 5 Vrms, 1 MΩ: 400 V max (DC + Peak AC ≤ 10 Khz) |
Input Coupling | 50 Ω: DC, GND; 1 MΩ: AC, DC, GND; |
Input Impedance | 50 Ω ± 2.0%;1 MΩ ± 2.0% / 15 pF, |
Offset Range | 50 Ω: 1 mV - 4.95 mV: ±1.6 V, 5 mV - 9.9 mV: ±4 V, 10 mV - 19.8 mV: ±8 V, 20 mV - 1 V: ±10 V |
1 MΩ: 1 mV - 4.95 mV: ±1.6 V, 5 mV - 9.9 mV: ±4 V, 10 mV - 19.8 mV: ±8 V, 20 mV - 100 mV: ±16 V | |
102 mV - 198 mV: ±80V, 200 mV - 1 V: ±160 V, 1.02 V -10 V: ±400 V | |
DC Vertical Offset Accuracy | ±(1.0% of offset value + 0.5%FS + 0.02% of max offset + 1mV) |
Analog - Acquisition | |
Sample Rate (Single-shot) | 2.5 GS/s |
Sample Rate (Repetitive) | 125 GS/s, user selectable for repetitive signals (20 ps/div to 10 ns/div) |
Record Length | Standard -STD: 50 Mpts/ch (all channels) |
Option - L: 100 Mpts/ch (all channels) | |
Option -XL: 250 Mpts/ch (all channels) | |
Acquisition Modes | Real-time, Roll, RIS (Random Interleaved Sampling), Sequence (Segmented Memory up to 30,000 segments, 60,000 segments -L Option, 65,000 -XL option) with 1us intersegment dead-time |
Timebase Range | 20 ps/div - 5 ks/div with standard memory (up to 10 ks/div with -L memory, 25 ks/div with -XL memory); RIS available at ≤ 10 ns/div; Roll Mode available at ≥ 100 ms/div and ≤ 5 MS/s |
Timebase Accuracy | ±2.5 ppm for 5 to 40C + 1.0ppm/year from calibration |
Channel-Channel Deskew Range | ±9 x time/div. setting, 100 ms max., each channel |
External Timebase Reference (Input) | 10 MHz ±25 ppm at 0 to 10 dBm into 50 Ω |
External Timebase Reference (Output) | 10 MHz 2.0 dBm ±1 dBm, sinewave synchronous to scope timebase |
External Clock | DC to 100 MHz; (50 Ω/1 MΩ), Ext. BNC input, Minimum rise time and amplitude requirements apply at low frequencies |
Analog - Acquisition Processing | |
Averaging | Summed averaging to 1 million sweeps; continuous averaging to 1 million sweeps |
Enhanced Resolution (ERES) | From 12.5- to 15-bits vertical resolution |
Envelope (Extrema) | Envelope, floor, or roof for up to 1 million sweeps |
Interpolation | Linear (Default) or Sin x/X |
Digital - Vertical and Acquisition (-MS Models Only) | |
Input Channels | 16 Digital Channels |
Threshold Groupings | Pod 2: D15 - D8, Pod 1: D7 - D0 |
Threshold Selections | TTL, ECL, CMOS (2.5 V, 3.3 V, 5 V), PECL, LVDS or User Defined |
Maximum Input Voltage | ±30V Peak |
Threshold Accuracy | ±(3% of threshold setting + 100mV) |
Input Dynamic Range | ± 20V |
Minimum Input Voltage Swing | 400mV |
Input Impedance (Flying Leads) | 100 kΩ / 5 pF |
Maximum Input Frequency | 250 MHz |
Sample Rate | 1.25 GS/s |
Record Length | Standard -STD: 50 MS - 16 Channels |
Optional -L: 100 MS - 16 Channels | |
Optional -XL: 125 MS - 16 Channels | |
Minimum Detectable Pulse Width | 2 ns |
Channel-to-Channel Skew | 350 ps |
User Defined Threshold Range | ±10 V in 20 mV steps |
User Defined Hysteresis Range | 100 mV to 1.4 V in 100 mV steps |
Triggering System | |
Modes | Auto, Normal, Single, Stop |
Sources | Any input channel, External, Ext/10, or line; slope and level unique to each source (except for line trigger) |
Coupling | DC, AC, HFREJ, LFREJ |
Pre-trigger Delay | 0-100% of memory size |
Post-trigger Delay | 0-10,000 Divisions in real time mode, limited at slower time/div settings or in roll mode |
Hold-off | From 2 ns up to 20 s or from 1 to 99,999,999 events |
Internal Trigger Level Range | ±4.1 div from center (typical) |
External Trigger Input Range | Ext: ±400 mV, Ext/10: ±4 V |
Maximum Trigger Rate | 1M Triggers/sec (in Sequence Mode, up to 4 channels) |
Trigger Sensitivity with Edge Trigger (Ch 1-4) | 0.9 division: 10 MHz |
1.0 divisions: 200 MHz | |
1.5 divisions: 500 MHz | |
2.0 divisions: 1 GHz | |
External Trigger Sensitivity, (Edge Trigger) | 0.9 division: 10 MHz |
1.0 divisions: 200 MHz | |
1.5 divisions: 500 MHz | |
2.0 divisions: 1 GHz | |
Max. Trigger Frequency, (C1-C4, Aux In, Smart Trigger) | 1 GHz |
Trigger and Interpolator Jitter | ≤ 3.5 ps rms (typical) |
<0.1 ps rms (typical, software assisted) | |
Trigger Types | |
Edge | Triggers when signal meets slope (positive, negative, or either) and level condition |
Width (Signal or Pattern) | Triggers on positive or negative glitches with selectable widths selectable as low as 200 ps (depending on oscilloscope bandwidth); Maximum Width: 20 s |
Pattern | Logic combination (AND, NAND, OR, NOR) of 5 inputs (4 channels and external trigger input). Each source can be high, low, or don't care. The High and Low level can be selected independently. Triggers at start or end of the pattern |
Measurement Trigger | Trigger on Measurement with qualified limits. |
TV-Composite Video | Triggers NTSC or PAL with selectable line and field; |
HDTV (720p, 1080i, 1080p) with selectable frame rate (50 or 60 Hz) and Line; or | |
CUSTOM with selectable Fields (1-8), Lines (up to 2000), Frame Rates (25, 30, 50, or 60 Hz), | |
Interlacing (1:1, 2:1, 4:1, 8:1), or Synch Pulse Slope (Positive or Negative) | |
Smart Triggers | |
Window | Triggers when signal exits a window defined by adjustable thresholds |
Interval (Signal or Pattern) | Triggers on intervals selectable between 1 ns and 20 s |
Glitch | Triggers on positive or negative glitches with widths selectable as low as 200 ps (depending on oscilloscope bandwidth) to 20 s, or on intermittent faults |
Dropout | Triggers if signal drops out for longer than selected time between 1 ns and 20 s |
Runt | Trigger on positive or negative runts defined by two voltage limits and two time limits. Select between 1 ns and 20 ns |
Slew Rate | Trigger on edge rates. Select limits for dV, dt, and slope. Select edge limits between 1 ns and 20 ns |
Multi-Stage Triggers | |
Cascade (Sequence) Triggering | |
Capability | Arm on “A" event, then Trigger on “B" event. Or Arm on “A" event, then Qualify on “B" event, and Trigger on “C" event. Or Arm on “A" event, then Qualify on “B" then “C" event, and Trigger on “D" event |
Types | A, B, C, or D event: Edge, Glitch, Width, Window, Dropout, Interval, Runt, Slew Rate, Pattern (analog), or Measurement. |
Holdoff | Holdoff between A and B, B and C, C or D, or any is selectable by time or number of events |
Qualified First | In Sequence acquisition mode, triggers repeatably on event B only if a defined pattern, state, or edge (event A) is satisfied in the first segment of the acquisition. Holdoff between sources is selectable by time or events |
Qualified | Triggers on any input source only if a defined state or edge occurred on another input source. Delay between sources is selectable by time or events |
TriggerScan | A Trigger Trainer analyzes the waveforms, identifies normal behavior, and then sets up a large set of rare event smart trigger setups that target abnormal behavior. The trainer ‘learns' trigger setups based on slew rates, periods, amplitudes outside of a range and then applies them sequentially. |
Triggers with Exclusion Technology | Glitch, Width, Interval, Runt, Slew Rate - Trigger on intermittent faults by specifying the expected behavior and triggering when that condition is not met |
Measurement Tools | |
Measurement Functionality | Display any 8 parameters together with statistics, including their average, high, low, and standard deviations. Histicons provide a fast, dynamic view of parameters and wave shape characteristics. Parameter Math allows addition, subtraction, multiplication, or division of two different parameters. Parameter gates define the location on the source waveform. Each occurrence of each parameter is measured and added to the statistics table. |
Measurement Parameters | Amplitude, Area, Base (Low), Cycles, Data, Delay, Delta Delay, Duty Cycle, Duration, Fall time (90-10%, 80-20%, @ level), Frequency, First, Last, Level @ x, Maximum, Mean, Median, Minimum, Narrow band phase, Narrow band power, Number of points, + Overshoot, - Overshoot, Peak-to-peak, Period, Risetime (10-90%, 20-80%, @ level), RMS, Std. deviation, Top, Width, Median, Phase, Time @ minimum (min.), Time @ maximum (max.), Delta time @ level, Delta time @ level from trigger, X @ max., X @ min., Cycle-Cycle Jitter, N-Cycle, N-Cycle with start selection, Frequency @ level, Period @ level, Half Period, Width @ level, Time Interval Error @ level, Setup, Hold, Skew, Duty Cycle @ level, Duty Cycle Error, Edge @ lv (counts edges) |
Math Tools | |
Math Functionality | Display up to 8 math function traces (F1-F8). The easy-to-use graphical interface simplifies setup of up to two operations on each function trace, and function traces can be chained together to perform math-on-math. |
Math Operators | Absolute value, Average (summed), Average (continuous), Correlation (two waveforms), Cubic interpolation, Derivative, Deskew (resample), Difference (-), Enhanced resolution (to 15 bits vertical), Envelope, Exp (base e), Exp (base 10), FFT (power spectrum, magnitude, phase, power density, real, imaginary, magnitude squared, up to 128 Mpts and rectangular, VonHann, Hamming, FlatTop and Blackman Harris windows), Floor, Integral, Interpolate (cubic, quadratic, sinx/x), Invert (negate), Log (base e), Log (base 10), Product (x), Reciprocal, Rescale (with units), Roof, (SINx)/x, Sparse, Square, Square root, Sum (+), Zoom (identity). 2 dual operator math functions may be defined at a time. |
Measurement and Math Integration | |
Histograms expanded with 19 histogram parameters and up to 2 billion events. Trend (datalog) of up to 1 million events. Track graphs of all parameters. Persistence histogram, persistence trace (mean, range, sigma) | |
Pass/Fail Testing | |
Test Types | Parameter limit testing, mask testing. Pass/Fail Actions include: Save, Stop, Alarm, Pulse, Hardcopy, LabNotebook |
Probes | |
Standard Probes | PP018 (5 mm) (Qty. 4) |
Probing System | BNC and Teledyne LeCroy ProBus for Active voltage, current and differential probes |
Display System | |
Display Size | Color 12.1" widescreen flat panel TFT-Active Matrix with high resolution touch screen |
Display Resolution | WXGA; 1280 x 800 pixels |
Number of Traces | Display a maximum of 16 traces. Simultaneously display channel, zoom, memory and math traces |
Grid Styles | Auto, Single, Dual, Quad, Octal, X-Y, Single+X-Y, Dual+X-Y, Tandem, Quattro, Twelve, Sixteen |
Waveform Representation | Sample dots joined, or sample dots only |
Connectivity | |
Ethernet | (2) 10/100/1000Base-T Ethernet interface (RJ-45 connector) |
USB Host Ports | (6) USB Ports Total - (2) Front USB Ports |
USB Device Port | (1) USBTMC Port |
GPIB Port (Optional) | Supports IEEE - 488.2 (External) |
External Monitor Port | Standard 15-pin D-Type SVGA-compatible DB-15 connector, DVI connector and HDMI connector |
Remote Control | Via Windows Automation, or via Teledyne LeCroy Remote Command Set |
Processor/CPU | |
Type | Intel Core i5, 2.5 GHz (or better) |
Processor Memory | 8 GB standard |
Operating System | Windows® Embedded Standard 7 Professional, 64-bit |
Power Requirements | |
Voltage | 100-240 VAC ±10% at 45-66 Hz; 100-120 VAC ±10% at 380-420 Hz; Automatic AC Voltage Selection; Installation Category: 300 V CAT II |
Power Consumption (Nominal) | 200 W / 200 VA |
Max Power Consumption | 350 W / 350 VA (with all PC peripherals and active probes connected to 4 channels) |
Environmental | |
Temperature | Operating: 5 °C to 40 °C; Non-Operating: -20 °C to 60 °C |
Humidity | Operating: 5% to 90% relative humidity (non-condensing) up to +31 °C, Upper limit derates to 50% relative humidity (non-condensing) at +40 °C; Non-Operating: 5% to 95% relative humidity (non-condensing) as tested per MIL-PRF-28800F |
Altitude | Operating: 3,048 m (10,000 ft) max at ≤ 30C; Non-Operating: Up to 12,192 meters (40,000 ft) |
Random Vibration | Operating : 0.31 grms 5 Hz to 500 Hz, 15 minutes in each of three orthogonal axes; Non-Operating: 2.4 grms 5 Hz to 500 Hz, 15 minutes in each of three orthogonal axes |
Functional Shock | 30 gpeak, half sine, 11 ms pulse, 3 shocks (positive and negative) in each of three orthogonal axes, 18 shocks total |
Physical | |
Dimensions (HWD) | 11.48"H x 15.72"W x 5.17"D (291.7 mm x 399.4 mm x 131.31 mm) |
Weight | 5.86 kg (12.9 lbs) |
Certifications | |
CE Certification | Low Voltage Directive 2006/95/EC |
EN 61010-1:2010, EN 61010-2-030:2010 | |
EMC Directive 2004/108/EC | |
EN 61326-1:2006, EN61326-2-1:2006 | |
UL and cUL Listing | UL 61010-1 (3rd Edition), UL 61010-2-030 (1st Edition); CAN/CSA C22.2 No.61010-1-12 |
Warranty and Service | |
3-year warranty; calibration recommended annually. Optional service programs include extended warranty, upgrades, and calibration services |