Hioki 3334-01

AC/DC Power HiTester w/GP-IB

Order #: 3334-01

Mfg #: 3334-01

Questions about availability or need help? Contact Us:

(800) 633-0561

Hioki 3334-01

AC/DC Power HiTester w/GP-IB

Order #: 3334-01

Mfg #: 3334-01

Availability:
This item is no longer available. Please contact Transcat Customer Service for assistance with alternative product suggestions to meet your exact needs.

Only need this item for a short time? Learn about rentals

Questions about this product? Speak to an expert

Product Highlights

  • DC measurement mode, AC, and AC+DC measurement possible
  • Integration function for current and power
  • High basic accuracy ±0.2%
  • Extended Period of Guaranteed Accuracy of 3 Years
  • Complete Accuracy Over a Wide Input Range 1.00mA? 30.00A, 0.150V? 300.0V, 0.0000W? 9.000kW
  • Measurement lines Single-phase/ two-wires
  • Measurement items Voltage, Current, Active power, Apparent power, Power factor, Frequency, Integration (current, active power), Waveform peak (voltage and current)
  • Measurement ranges [Voltage] AC/DC 15.000/30.00/150.00/300.0V
  • [Current] AC/DC 100.00/300.0 mA, 1.0000/3.000/10.000/30.00A
  • [Power] 1.5000 W?9.000 kW (combination of voltage and current ranges)
  • Integration measurement
  • Integration time up to 10,000 hours [Current] No.of displayed digits: 6 digits (from 0.00000mAh, Polarity-independent integration and Sum value)
  • [Active power] No.of displayed digits: 6 digits (from 0.00000mWh, Polarity-independent integration and Sum value)
  • Input resistance 2.4MO for voltage, 10mO or better for current, (50/60 Hz, direct input)
  • Basic accuracy ±0.1%rdg. ±0.2%f.s. (DC), ±0.1%rdg. ±0.1%f.s. (45Hz to 66Hz)
  • Note: Provided accuracy of 1 Year, typical value
  • Display refresh rate 5 times per second
  • Frequency characteristics DC, 45Hz to 5kHz
  • Waveform output Parameter output representation: voltage, current and active power (3 simultaneous channels), Output voltage: 1V DC f.s.
  • Analog output
  • (D/A output) Parameter output representation: voltage, current active power and selected 1 item (4 simultaneous channels), Selected 1 item from apparent power, power factor, current integration, active power integration, Output voltage: ±2V DC f.s.
  • Functions Rectification method switchable between AC+DC (True RMS), DC (simple average), AC (True RMS), Wave peak measurement, VT or CT ratio settings, Average function
  • Interface RS-232C included as standard, GP-IB (Model 3334-01 only)
  • Power consumption 100V to 240V AC, 50/60Hz, 20VA max.
  • Dimensions and mass 210 (8.27in) W × 100 (3.94in) H × 245 (9.65in) D mm, 2.5kg (88.2oz)

Each Unit Includes

  • Power cord

Special Member Pricing
Buy with Calibration
Rental Instruments
Access to 100,000+ products
1,000's of instruments in stock
Product selection expertise
Application assistance
Purchase with a PO