Rotronic HC2A-S3

Standard Probe:Accuracy for Meteorology Applications

Order #: HC2A-S3

Mfg #: HC2A-S3

Questions about availability or need help? Contact Us:

(800) 633-0561
$464.71

Rotronic HC2A-S3

Standard Probe:Accuracy for Meteorology Applications

Order #: HC2A-S3

Mfg #: HC2A-S3

$464.71
The HC2A-S3 is the most versatile probe from ROTRONIC and forms the basis of the product portfolio. It measures humidity and temperature and calculates the dew/frost point.
Availability: Item ships in about Ships in 1-2 weeks
Available Promotions

Only need this item for a short time? Learn about rentals

Questions about this product? Speak to an expert

Product Highlights

  • Accuracy: ±0.8 %rh, ±0.1 K, at 23 °C ±5 K
  • Range of application: -50…100 °C / 0…100 %rh
  • Digital interface (UART) and scalable analog outputs, 0…1 V
  • Standard output scaling: 0…1 V = -40…60 °C / 0…100 %rh
  • Adjusted at 23 °C and 10, 35, 80 %rh
  • Probe type Meteorological probe
  • Operating range -50…100 °C / 0…100 %rh
  • Accuracy w. adjustment profile "standard" ±0.8 %RH / ±0.1 K, at 10...30 °C Adjustment at 23 °C and 10, 35, 80 %RH
  • Accuracy w. adjustment profile "High Precision" ±0.5 %RH / ±0.1 K, at 10...30 °C at 23 °C and 10, 20, 30, 40, 50, 60, 70, 80, 90 %RH
  • Power supply / Power consumption 3.3...5 VDC, Calibration @ 3.3 VDC / ~4.5 mA
  • Long-term stabilityHumidity sensor Hygromer HT-1
  • Temperature sensor PT100 1/3 DIN Class B
  • Probe protection Polycarbonate plastic cage, white
  • Filter cartridge Polyethylene dust filter, white, 40 um
  • Filter type Polyethylene, 40 μm
  • Response time t 63Allowed wind speed 20 m/s, with filter
  • Psychrometric calculations Dew or frost point
  • Reproducibility AirchipExploitation software ROTRONIC HW4
  • Probe adjustment by software 1 Point & multipoint %rh & °C
  • Firmware update With internet and HW4 software
  • User information from Software HW4 (devicemanager)
  • Data processing via HW4 with interface cables
  • Device Protection by password Yes
  • Type of output signals 2 x 0…1 VDC
  • Analogue outputs scaleable by the user Yes
  • Analog output signal (standard) 0…1 V = 0…100 %rh; 0…1 V = -40…60 °C
  • Digital output signal (standard) UART
  • Communication interfaces UART
  • Service Interface UART
  • Reverse voltage protection Mechanically in the connector
  • Max. cable length Up to 5 m with passive cable. Up to 100 m with active cable.
  • Enclosure material Polycarbonate
  • FDA/GAMP compatibility FDA 21 CFR Part 11 and GAMP compatible
  • Dimensions Ø15 x 108 mm
  • Weight 17 g

Special Member Pricing
Buy with Calibration
Rental Instruments
Access to 100,000+ products
1,000's of instruments in stock
Product selection expertise
Application assistance
Purchase with a PO