Endress+Hauser TMT82-F3A2GB1A1AAA1+PA

iTEMP Temp. Trans.,FM XP, HART, RTD 3-wire,Pt100, -200-850C

Order #: TMT82-F3A2GB1A1AAA1+PA

Mfg #: TMT82-F3A2GB1A1AAA1+PA

Questions about availability or need help? Contact Us:

(800) 633-0561
Special Price $589.63 Regular Price $640.91

Endress+Hauser TMT82-F3A2GB1A1AAA1+PA

iTEMP Temp. Trans.,FM XP, HART, RTD 3-wire,Pt100, -200-850C

Order #: TMT82-F3A2GB1A1AAA1+PA

Mfg #: TMT82-F3A2GB1A1AAA1+PA

Special Price $589.63 Regular Price $640.91
See our Endress + Hauser iTEMP TMT82 Family Page for an ordering guide and all configurations.
Unsurpassed reliability, accuracy and long-term stability in critical processes over all industries. The configurable transmitter not only transfers converted signals from resistance thermometers (RTD) and thermocouples (TC), but also resistance and voltage signals using HART® communication. High measurement point availability by means of sensor monitoring functions. Diagnostics information according to NAMUR NE 107. Optimization of the measurement accuracy by sensor-transmitter matching.
Availability: Ships in 3-4 Weeks
Available Promotions

Only need this item for a short time? Learn about rentals

Questions about this product? Speak to an expert

Product Configuration

  • F3 Approval: FM XP, NI, DIP I, II, III/1+2/A-G
  • A Communication; Output Signal: HART; 4-20 mA, 2 channel
  • 2 Electrical Connection: Screw terminals, housing form B, DIN EN 50446
  • G Field Housing: TA30H; 2x 1/2NPT; glass display window, explosionproof enclosure
  • B1 Configuration Universal Input: Ch1: RTD 3-wire, Ch2: inactive
  • A1 Sensor Type Input 1: Pt100, -200...850oC, min. span 10K, IEC60751 (a = 0.00385)
  • AA Sensor Type Input 2: Inactive
  • A1 Input; Interconnection: PV = CH1; CH2 inactive
  • PA >>Accessory Enclosed: Mounting bracket wall, 316L

Product Highlights

  • Certified up to SIL 2/3 - hardware/software - according to IEC 61508:2010
  • Safe operation in hazardous areas, international approvals such as FM IS, NI; CSA IS, NI; ATEX, NEPSI, IECEx Ex ia, Ex nA for intrinsically safe installation in zone 1 and zone 2
  • HART® 7 version
  • High accuracy of measuring point through sensor-transmitter matching
  • Reliable operation with sensor monitoring and device hardware fault recognition
  • Diagnostics information according to NAMUR NE107
  • Rapid no-tools wiring due to optional spring terminal technology