SMC ETP-1

Transformer Turns Ratio Measurement Unit

The measurement equipment ETP-1 is a unit that automatically performs measurements on all types of power, distribution or instrument transformers.

Order #: ETP-I

Mfg Part #: ETP I

$21,050.00 USD
 
 

Usually ships in 7-10 days

Free shipping over $250

This product is available for shipping to United States only

Add Items to Cart

Request a Calibration Quote

Transcat can calibrate your existing instruments.

Request a Calibration Quote

Rent From Transcat

Do you need a test instrument for a short time?

Request a Rental Quote

click on image to view gallery image(s)

View All SMC Products

Compare Products in this Series See all Results

Product
Image
NAME, DESCRIPTION
AND ORDER #
Stock
Status
UNIT PRICE QTY
SMC ETP-4 SMC ETP-4

Transformer Short Circuit Impedance Measurement Unit

Order #: ETP-IV

Usually ships in 7-10 days

$20,200.00 USD
Add Items to Cart Add to Quote

SMC ETP-3 SMC ETP-3

Transformer Winding Resistance Measurement Unit

Order #: ETP-III

Usually ships in 7-10 days

$26,000.00 USD
Add Items to Cart Add to Quote

SMC ETP-2 SMC ETP-2

Recovery Voltage and Insulation Evaluation Unit

Order #: ETP-II

Usually ships in 7-10 days

$35,100.00 USD
Add Items to Cart Add to Quote

SMC EDA-III SYSTEM SMC EDA-III SYSTEM

Insulation Evaluation System for Motors and Generators

Order #: EDA-III-SYSTEM

Usually ships in 7-10 days

$46,950.00 USD
Add Items to Cart Add to Quote

SMC ETP SYSTEM SMC ETP SYSTEM

Predictive Maintenance System for Power Transformers

Order #: ETP-SYSTEM

Usually ships in 7-10 days

$90,167.00 USD
Add Items to Cart Add to Quote

Overview :

The measurement equipment ETP-1, is a unit that automatically performs the following measurements on all types of power, distribution or instrument transformers:

    Product Highlights

  • Actual turn ratio for each position of the tap changer.
  • No load current and power, at the test voltage.
  • Polarity and phase angle between voltages and voltage/current.
  • Automatically calculates results according with the connection group.
  • The connection to the transformer taps is guided from the computer to avoid connection errors.
  • Enables to select the number of the tap changer positions to be measured, as the software informs the position that should be measured each time.
  • For each tap changer position, a three phase automatic measurement is performed. It is not necessary to change the connection to the transformer taps.
  • The no load test current waveform is presented on the computer screen. It detects possible problems in the iron core.
  • The test time for each three phase test position is less than 10 seconds.
  • The measuring range has a ratio between 1:1 to 3000:1.
  • Applications:
    • Quality Control after the manufacturing process.
    • Reception of new or repaired transformers.
    • Detection of possible problems during the maintenance task itself.
    • Integrates the data inside a predictive maintenance program.

Through the Turn Ratio Measurement and the ability to show this on line in a comparative graphic form for each of the tap changer position, possible problems of the wiring and/or in the tap changer such as short-circuit between turns, bad contacts, incorrect internal connection, open circuits, etc…, can be easily detected. Using the value and waveform of the excitation current (No Load Current), possible problems in the iron core can be easily detected as well.

The power loss, the phase angle between the primary and secondary voltages (V1/V2), and the phase angle between primary voltage and its current, is measured and shown to the user. These values and its relationship offer confirmation of the possible problems detected with the other measurements.

The Transformer Turn Ratio Measurement ETP-1 has a number of unique features which allows a substantial difference in application terms, with other TTR units that exist on the market. The biggest advantage is the speed of the test (less than 10s per tap changer position) enabling the testing of all the positions in a very short time. Not only this, but the results are automatically stored in a file, presented on the screen in figures and graphic terms and are very easy accessible for further analysis, if desired. The unit measures (phase to phase) in less than ten seconds per position, and presents the measured or calculated values of the following parameters:

  • Turn ratio per phase, according with the connection group.
  • Phase angle between primary and secondary voltage.
  • Phase angle between primary current and voltage.
  • Waveform of the primary current.
  • Waveform of the primary and secondary voltage.
  • Apparent (VA), reactive (VAR) and active (W) power at the test voltage.
  • RMS value of the no load current at the test voltage.

The software control, accordingly with the type and group of connection that the transformer under test has, delivers the connection instructions to the operator through a color code avoiding connection errors. The software also allows selecting the type of tap changer, number of positions, and the number of taps to be tested. This selection configures a result score filled with all the results per position. Also it automatically presents a comparative graphic between the theoretical and actual measured values for each tap changer position. The following types of voltage transformers can be tested with the ETP-1, despite the size and power:

  • Power Transformers (single or three phase).
  • Distribution Transformers (single or three phase).
  • Power Autotransformers (single or three phase).
  • Instrument Voltage Transformers.

Accessories :