0 Item(s)

Hioki IM3590

Chemical Impedance Analyzer

Order #: IM3590

Mfg Part #: IM3590

$9,295.00 USD
 
 

Usually ships in 7-10 days

Free shipping over $250

Add Items to Cart

Request a Calibration Quote

Transcat can calibrate your existing instruments.

Request a Calibration Quote

Rent From Transcat

Do you need a test instrument for a short time?

Request a Rental Quote

click on image to view gallery image(s)

View All Hioki Products

Overview :

Product Highlights

  • Basic accuracy of ±0.05%, broad measurement frequency range of 1 mHz to 200 kHz as well as DC capabilities and high-speed measurement at up to 2 ms
  • Cole-Cole plot display
  • Electrochemical material and component equivalent circuit analysis
  • Supports low-frequency measurements starting at 1 mHz
  • Frequencies as low as 1 mHz are needed to measure the electrochemical impedance of phenomena such as ion behavior. With an upper frequency limit of 200 kHz, Model IM3590 can also be used to measure properties such as solution resistance.
  • Display a variety of graphs, including Cole-Cole plots
  • The IM3590 can perform frequency sweep measurement at up to 801 points and display Cole-Cole plots. It can also perform level-sweep and time-interval measurements.
  • Measure 18 parameters, including dielectric constant and conductivity
  • In addition to Z, Y, ?, Rs (ESR), Rp, Rdc (DC resistance), X, G, B, Ls, Lp, Cs, Cp, D (tan s), Q, and T, the IM3590 can measure the dielectric constant (e) and conductivity (s).
  • Equivalent circuit analysis of electrochemical materials and components
  • The IM3590 provides four electrochemical component models and is capable of isolating and analyzing properties such as charge transfer resistance and electric double layer capacitance. It also provides five equivalent circuit analysis types for normal circuit elements, materials, and components

Specifications :

Measurement modesLCR mode, Continuous measurement mode (LCR mode / Analyzer mode), Analyzer mode (Sweeps with measurement frequency and measurement level, temperature characteristics, equivalent circuit analysis)
Measurement parametersZ, Y, θ, Rs (ESR), Rp, Rdc (DC resistance), X, G, B, Cs, Cp, Ls, Lp,
D (tanδ), Q, T, σ (conductivity), ε (dielectric constant)
Measurement range100 mΩ to 100 MΩ, 10 ranges (All parameters are determined according to Z)
Display rangeZ, Y, Rs, Rp, Rdc, X, G, B, Ls, Lp, Cs, Cp, σ, ε :
±(0.00000 [unit] to 9.99999G [unit], Absolute value display for Z and Y only
θ : ±(0.000° to 180.000°), D : ±(0.00000 to 9.99999)
Q : ±(0.00 to 99999.9), Δ % : ±(0.0000% to 999.999%)
T : -10.0°C to 99.9°C
σ, ε :±(0.00000f [unit] to 999.999G [unit]
Basic accuracyZ: ±0.05% rdg. θ: ±0.03°
Measurement frequency1 mHz to 200 kHz (5 digits setting resolution, minimum resolution 1 mHz)
Measurement signal levelNormal mode:
V mode/CV mode: 5 mV to 5 Vrms, 1 mVrms steps
CC mode: 10 μA to 50 mArms, 10 μArms steps
Low impedance high accuracy mode:
V mode/CV mode: 5 mV to 2.5 Vrms, 1 mVrms steps
CC mode:10 μA to 100 mArms, 10 μArms steps
Output impedanceNormal mode: 100 Ω, Low impedance high accuracy mode: 25 Ω
Display5.7-inch color TFT, display can be set to ON/OFF
Measurement time2 ms (1 kHz, FAST, display OFF, representative value)
FunctionsDC bias measurement, DC resistance temperature compensation (converted reference temperature is displayed), Temperature measurement, Battery measurement (Automatic DC biasing system), Comparator, BIN measurement (classification), Panel loading/saving, Memory function
InterfacesEXT I/O (Handler), USB communication (high-speed), USB memory
Optional: Choose 1 from RS-232C, GP-IB, or LAN
Power supply100 to 240 V AC, 50/60 Hz, 50 VA max.
Dimensions and mass330 mm (12.99 in) W × 119 mm (4.69 in) H × 168 mm (6.61 in) D, 3.1 kg (109.3 oz)
AccessoriesPower cord × 1, Instruction manual × 1, CD-R (Communication instruction manual and sample software [Communications control, accuracy calculation, and screen capture functionality] ) × 1