Hioki 8206-10

Dual Channel Voltage & Current Recorder

Order #: 8206-10

Mfg Part #: 8206-10

$1,725.00 USD
 
 

This product is currently not available.

Request a Calibration Quote

Transcat can calibrate your existing instruments.

Request a Calibration Quote

Rent From Transcat

Do you need a test instrument for a short time?

Request a Rental Quote

click on image to view gallery image(s)

View All Hioki Products Discontinued Product

Overview :

Product Highlights

  • Direct current measurement of up to 1000A
  • Fast LCD level meter to quickly display measured level
  • True RMS rectification system
  • Climate-resistant recording paper
  • Sampling rate of 100 samples/second with selectable chart speeds
  • Two channels for recording of AC voltage and AC current simultaneously
  • Measurement ranges AC Voltage: 100/200/500 V f.s. 3 ranges
  • AC Current: 10 A to 100 A AC 4 ranges (with separate clamp on sensor 9650)
  • AC Current: 10 A to 500 A AC 6 ranges (with optional separate on sensor 9651)
  • AC Current: 10 A to 1000 A AC 7 ranges (with separate clamp on sensor 9668)
  • Sampling period: 10 ms
  • Frequency characteristic AC/DC voltage range: +0.5 dB to -3 dB from 30 Hz to 30 kHz
  • AC current range: Frequency characteristic is determind by the clamp sensor
  • Paper feed speed: 60 cm/hour to 2 cm/hour (5 ranges)
  • Number of input channels: 1 channel AC voltage and 1 channel AC current
  • Simultaneous recording based on two channel alternating sampling
  • For commercial power lines, input is voltage isolated
  • Accuracy Voltage: ±2 % f.s. (45 Hz to 66 Hz)
  • Current: ±3.53 % f.s. (used with separate clamp on sensor 9651/option, AC 500 A range)
  • Power supply: 100 to 240 V AC (50/60 Hz) or 9.5 to 14 V DC, 2 way
  • Dimensions: 250 mm (9.4 in) W × 122 mm (4.8 in) H × 93.5 mm (3.66 in) D
  • Mass: 1.2 kg (42.33 oz)

Each Unit Includes

  • Recording paper 9235 (One roll)
  • Roll paper holder (Two)
  • Power cord
  • Connection cord 9257
  • Carrying case 9344