The Endress+Hauser RIA45 Process Meter with Control Unit

Analog measured values are indictated, evaluated and calculated by the process meter. With the integrated loop power supply two-wire sensors can be powered. The universal inputs enable the connection of current, voltage, RTDs and TCs. Limit values can be monitored and relays can be switched. Via analog outputs process signals can be forwarded. The integrated application package "differential pressure" allows the quick and easy commissioning for differential pressure applications.

Compare Products in this Series See all Results

Product
Image
NAME, DESCRIPTION
AND ORDER #
Stock
Status
UNIT PRICE QTY
Endress+Hauser RIA45-A1A1 Endress+Hauser RIA45-A1A1

Panel Mount Process Meter with Control Unit, 1x Uni. & analog

Order #: RIA45-A1A1

Usually ships in 7-10 days

$522.00 USD
Add Items to Cart Add to Quote

Endress+Hauser RIA45-A1C1 Endress+Hauser RIA45-A1C1

Panel Mount Process Meter with ControlUnit,1xUni./analog +2Rly

Order #: RIA45-A1C1

Usually ships in 7-10 days

$626.00 USD
Add Items to Cart Add to Quote

Overview :

Product Highlights

  • 5-digit 7-segment LC display, backlit
  • 1 or 2 universal inputs
  • 2 relays (optional)
  • Min./max. value saved
  • 1 or 2 calculated values and linearization table
  • Digital status output (Open Collector)
  • SIL2 approval (optional)

Field of Application

The RIA45 panel meter exhibits a display, analog inputs for process and status signals, analog and digital outputs, and an interface for configuration. Connected sensors can be powered by the integrated LPS. All measured and calculated values are available as a signal source for display, outputs, relays and the interface.

  • Plant and apparatus engineering and construction
  • Control rooms and cabinets
  • Laboratories
  • Process recording and supervision
  • Process control
  • Signal adjustment and conversion

Specifications :

Acquisition / Evaluation
Measuring PrincipleResistance Temperature Detector
FunctionDisplay
Loop power supply
Transmitter functionality
Barrier
Signal isolation
Calculation
Limit alarm
CertificationATEX II (1)GD[Ex ia] 4C
CSA AIS, NI/I/2 ABCDEFG/T4
FM AIS, NI/I/2 ABCDEFG/T4 GL marine certificate
Input2 x universal (U, I, R, RTD, TC)
Output2 x analogue output (I, U)
1 x loop power supply
Relay output2 x changeover contact
1 x open collector
Auxiliary power supply / Loop power supply 20...250V AC/DC
Dimensions (wxhxd)Panel housing:
96 x 48 x 175 mm
(3.78" x 1.89" x 6.89")
SoftwareLinearization
Minimum value per channel
Maximum value per channel
Calculation
Band value monitoring
Operation3 keys
Interface CDI to USB at PC + configuration software FieldCare
DisplayMulticolor backlight LCD
White/black/yellow
Bargraph
Unit
TAG
Alarm warning in plain text
Thermometer
Measuring PrincipleResistance Temperature Detector
Characteristic / ApplicationDisplay
Loop Power Supply
Transmitter Functionality
Barrier
Signal Isolation
Calculation
Limit Alarm

Ex - approvalsATEX EE Ex ia
CSA NI
FM