Endress+Hauser iTEMP TMT142 Temperature Field Transmitter
Endress+Hauser iTEMP TMT142 Temperature Field Transmitter
Order #: Endress+Hauser iTEMP TMT142 Temperature Field Transmitter
Endress+Hauser iTEMP TMT142 Temperature Field Transmitter
Endress+Hauser iTEMP TMT142 Temperature Field Transmitter
Order #: Endress+Hauser iTEMP TMT142 Temperature Field Transmitter
Unsurpassed reliability, accuracy and long-term stability in critical processes over all industries. The configurable transmitter not only transfers converted signals from RTD sensors and thermocouples, but also resistance and voltage signals using HART® communication. It visualizes the signals on its own backlit display. A rugged field housing allows a direct connection in the process areas. Moreover, a swift and easy operation and maintenance can be realized by PC using operating software.
Availability: Ships in 2-3 Weeks
Product Highlights
- Illuminated display, rotatable
- Operation, visualisation and maintenance with PC, e.g. using FieldCare operating software
- Sensor monitoring: Failure conditioning, corrosion detection to NAMUR NE 89 and in event of sensor break or sensor short-circuit, NAMUR NE 43 compliant
- Optional stainless steel housing for EEx d applications
- Approvals: ATEX (EEx ia, EEx d and dust ignition-proof), FM and CSA (IS, NI, XP and DIP)
- Galvanic isolation
- Min./max. process value recorded
Field of Application
- Temperature field transmitter with HART® protocol for converting various input signals to a scalable 4...20 mA analog output signal
- Universal input usable for: Resistance thermometer (RTD), thermocouples (TC), resistance transmitter (Ω) and voltage transmitter (mV)
- HART® protocol for operating the device on site using handheld terminal (DXR375) or remotely via the PC
- Optional stainless steel housing for EEx d applications
Temperature Transmitters | |
---|---|
Measuring Principle | Field transmitter |
Input | 1 x RTD, TC, Ohm, mV |
Output | 1 x analog 4...20 mA |
Auxiliary power supply | 10,5...40 V DC (standard-version) 10,5...30 V DC (Ex-version) |
Communication | HART-protocol |
Installation | in field |
Accuracy | (Pt100, -50...200 °C) <=0,15 K (Pt100, -58...392 °F) <=0,3 °F |
Galvanic isolation | yes |
Certification | UL rec. Comp FM IS, NI I/1+2/A-D ATEX II1G Ex ia IIC T6 ATEX II2G Ex d IIC T6 ATEX II3G Ex nA IIC T6 ATEX IECEx II2D Ex tb IIIC Db ATEX II1G Ex ia IIC T6, II2D Ex ia IIIC CSA IS, NI I/1+2/A-D FM XP, NI, DIP I,II,III/1+2/A-G CSA XP, NI, DIP I,II,III/1+2/A-G CSA General Purpose IECEx Ex ia IIC T6 Ga IECEx Ex d IIC T6 Gb NEPSI Ex ia IIC T4-T6 NEPSI Ex nA II T4-T6 NEPSI Ex d IIC T4-T6 |