The Endress+Hauser Cerabar PMP71 Absolute and Gauge Pressure Transmitter
Endress+Hauser Cerabar PMP71 Absolute and Gauge Pressure Transmitter

Order #: Endress+Hauser Cerabar PMP71 Absolute Pressure Transmitter

Questions about availability or need help? Contact Us:

(800) 633-0561

The Endress+Hauser Cerabar PMP71 Absolute and Gauge Pressure Transmitter

Endress+Hauser Cerabar PMP71 Absolute and Gauge Pressure Transmitter

Order #: Endress+Hauser Cerabar PMP71 Absolute Pressure Transmitter

The Cerabar PMP71 digital pressure transmitter with metallic membrane is typically used in process applications for pressure, level, volume or mass measurement in liquids or gases. PMP71 is designed for high pressure applications up to 700bar. Quick Setup with freely adjustable measuring range without pressure specification. Designed according to IEC 61508 for use in SIL2/3 safety systems and available with MID Parts Certificate suitable for custody transfer applications.

Availability: Ships in 2-3 Weeks
Grouped product items
Product Name Qty
No options of this product are available.

Product Highlights

  • Best accuracy, reproducibility and long-term stability
  • Highest safety due to gastight feedthrough with capabilities up to SIL2/3, certified to IEC 61508
  • Easy menu-guided commissioning via local display, 4 to 20mA with HART, PROFIBUS PA, FOUNDATION Fieldbus
  • HistoROM data management concept for fast and easy commissioning, maintenance and diagnostics
  • Overload-resistant and function-monitored from the measuring cell to the electronics
  • Cost savings with modular concept for easy replacement of sensor, display or electronics
  • Seamless and independent system integration (HART/PA/FF)

Field of Application

Two chamber aluminum or stainless steel (316L) housing.

  • Process connections: Threads and flange connections
  • Process temperature: -40 to +125°C (-40 to +257°F)
  • Measuring ranges: -1/0 up to 700bar (-15/0 up to +10,500psi)
  • Accuracy: ±0.075%, "Platinum" ±0.05%
  • International explosion protection certificates, overfill prevention WHG, hygienic approvals, marine approvals, SIL
Win a Generac Generator when purchasing $750 or more from Transcat.Win a Generac Generator when purchasing $750 or more from Transcat.
Continuous/Liquids
Measuring Principle Hydrostatic
Characteristic / Application Digital transmitter with piezoresistive sensor and welded metallic membrane
Modular transmitter
Long term stability
Enhanced safety via self diagnostic functions
Secondary process barrier
Supply / Communication 4...20mA HART:
10,5...45V DC
Ex ia: 10,5...30V DC
PROFIBUS PA /
FOUNDATION Fieldbus:
9...32V DC
Accuracy 0,075% "PLATINUM" 0,05%
Long Term Stability 0,05% of URL/year
Ambient Temperature -40°C...85°C (-40°F...185°F)
Process Temperature -40°C...125°C (-40°F...257°F)
Process Pressure Absolute / Max. Overpressure Limit 1050bar (15,750psi)
Pressure Measuring Range 100mbar...700bar (1.5psi...10.500psi)
Main Wetted Parts Alloy C276
316L
Rhodium
Process Connection Threads
Flanges (DIN, ASME, ...) with flush membrane
Max. Measurement Distance 7000m (22.966ft) H2O
Output 4...20 mA HART
PROFIBUS PA
FOUNDATION Fieldbus
Certificates / Approvals ATEX, FM, CSA, CSA C/US, IEC Ex, TIIS, INMETRO, NEPSI
SIL
WHG/ overspill protection
EN10204-3.1
NACE
Marine
Options HistoROM/M-Dat
4-line digital display
SS- or Aluminiumhousing
Separate housing
Specialities diagnostic functionalities
different languages in software
Application Limits Measuring cell: Metal welded If pressurized, possibly use differential pressure meas-urement with two pressure transmitters (electronic dp). Observe ratio head pressure : hydrostatic pressure


Pressure
Measuring Principle Differential pressure
Characteristic Digital transmitter with metallic measuring diaphragms
Compact size
Modular transmitter
Long-term stability
Supply Voltage 4...20mA HART
11,5...45V DC (Non Ex):
Ex ia: 11,5...30V DC
PROFIBUS PA:
9...32 V DC (Non Ex)
FOUNDATION Fieldbus:
9...32 V DC (Non Ex)
Reference Accuracy 0,1% "PLATINUM" 0,075%
Long Term Stability 0,05% of URL/year 0,125% of URL/5 years
Ambient Temperature -40°C...85°C (-40°F...185°F)
Process Temperature -40°C...120°C (-40°F...248°F)
Measuring Cell 10mbar...40bar (0.15...580psi)
Smallest Calibratable Span 0.5 mbar (0.0075 psi)
Max. Turn Down 100:1
Max. Overpressure Limit On One Side: 160 bar (2300 psi)
Process Connection 1/4-18 NPT
Material Process Membrane 316L, AlloyC
Material Gasket Viton, PTFE, EPDM, NBR
Fill fluid Silicone oil, Inert oil
Material Housing Die-cast aluminum
Output 4...20mA HART
PROFIBUS PA
FOUNDATION Fieldbus
Certificates / Approvals ATEX, FM, CSA, CSA C/US, IEC Ex, TIIS, INMETRO, NEPSI
NACE
SIL
EN10204-3.1
Options 4-line digital display
Aluminium housing


Continuous/Liquids
Measuring Principle Hydrostatic
Characteristic / Application Digital transmitter with piezoresistive sensor and welded metallic membrane
Modular transmitter
Long term stability
Enhanced safety via self diagnostic functions
Secondary process barrier
Supply / Communication 4...20mA HART:
10,5...45V DC
Ex ia: 10,5...30V DC
PROFIBUS PA /
FOUNDATION Fieldbus:
9...32V DC
Accuracy 0,075% "PLATINUM" 0,05%
Long Term Stability 0,05% of URL/year
Ambient Temperature -40°C...85°C (-40°F...185°F)
Process Temperature -40°C...125°C (-40°F...257°F)
Process Pressure Absolute / Max. Overpressure Limit 1050bar (15,750psi)
Pressure Measuring Range 100mbar...700bar (1.5psi...10.500psi)
Main Wetted Parts Alloy C276
316L
Rhodium
Process Connection Threads
Flanges (DIN, ASME, ...) with flush membrane
Max. Measurement Distance 7000m (22.966ft) H2O
Output 4...20 mA HART
PROFIBUS PA
FOUNDATION Fieldbus
Certificates / Approvals ATEX, FM, CSA, CSA C/US, IEC Ex, TIIS, INMETRO, NEPSI
SIL
WHG/ overspill protection
EN10204-3.1
NACE
Marine
Options HistoROM/M-Dat
4-line digital display
SS- or Aluminiumhousing
Separate housing
Specialities diagnostic functionalities
different languages in software
Application Limits Measuring cell: Metal welded If pressurized, possibly use differential pressure meas-urement with two pressure transmitters (electronic dp). Observe ratio head pressure : hydrostatic pressure


Pressure
Measuring Principle Hydrostatic
Characteristic Digital transmitter with piezoresistive sensor and welded metallic membrane
Modular transmitter
Long term stability
Enhanced safety via self diagnostic functionsSecondary process barrier
Supply Voltage 4...20mA HART
10,5...45V DC (Non Ex):
Ex ia: 10,5...30V DC
PROFIBUS PA:
9...32 V DC (Non Ex)
FOUNDATION Fieldbus:
9...32 V DC (Non Ex)
Reference Accuracy Standard: 0.05%
Platinum: up to 0.025%
Long Term Stability 0,05% of URL/year
Ambient Temperature -40°C...85°C (-40°F...185°F)
Process Temperature -40°C...125°C (-40°F...257°F)
Measuring Cell 100mbar...700bar (1.5psi...10.500psi) relative/ absolute
Smallest Calibratable Span 5 mbar (0.075 psi)
Vacuum resistance 10 mbar (1.45 psi)
Max. Turn Down 100:1
Max. Overpressure Limit 1050bar (15.750psi)
Process Connection Thread: G1/2...G2, R1/2, MNPT1/2...MNPT2, R1/2
Flange: DN25...DN80, ASME 1"...4", JIS 10K...20K
Material Process Membrane 316L, AlloyC, Rhodium, Gold
Material Gasket None, measuring cell welded
Fill fluid Silicone oil, Inert oil
Material Housing Die-cast aluminum, AISI 316L
Output 4...20mA HART
PROFIBUS PA
FOUNDATION Fieldbus
Certificates / Approvals ATEX, FM, CSA, CSA C/US, IEC Ex, TIIS, INMETRO, NEPSI
Overfill prevention WHG
SIL
EN10204-3.1
NACE
GL/ABS Marine
NSF Drinking water
Options HistoROM/M-Dat
4-line digital display
SS- or Aluminiumhousing
Separate housing
Specialities Diagnostic functions