0 Item(s)

click on image to view gallery image(s)

The Endress+Hauser Cerabar PMP51 Absolute and Gauge Pressure Transmitter

The Cerabar PMP51 digital pressure transmitter with metal membrane is typically used in process and hygiene applications for pressure, level, volume or mass measurement in liquids or gases. PMP51 is designed for high pressure applications up to 400bar. Quick Setup with adjustable measuring range allows simple commissioning, reduces costs and saves time. SIL2 according to IEC 61508 and IEC 61511.

Compare Products in this Series See all Results

Product
Image
NAME, DESCRIPTION
AND ORDER #
Stock
Status
UNIT PRICE QTY
Endress+Hauser PMP51-AA12ID1PGFRLJA1 Endress+Hauser PMP51-AA12ID1PGFRLJA1

Cerabar Pressure Transmitter, 4-20mA, 150psi gauge

Order #: PMP51-AA12ID1PGFRLJA1

Usually ships in 7-10 days

$945.00 USD
Add Items to Cart Add to Quote

Endress+Hauser PMP51-FB22ID1WGFRKJA1 Endress+Hauser PMP51-FB22ID1WGFRKJA1

Cerabar Pressure Transmitter, FM XP, HART, 6000psi gauge

Order #: PMP51-FB22ID1WGFRKJA1

Usually ships in 7-10 days

$1,154.00 USD
Add Items to Cart Add to Quote

Endress+Hauser PMP51-8B21JD1WGFRKJA1 Endress+Hauser PMP51-8B21JD1WGFRKJA1

Cerabar Pressure Transmitter, IS/HART/LCD, 6000psi gauge

Order #: PMP51-8B21JD1WGFRKJA1

Usually ships in 7-10 days

$1,243.00 USD
Add Items to Cart Add to Quote

Endress+Hauser PMP51-AA21JD1PGFRLJA1+P2 Endress+Hauser PMP51-AA21JD1PGFRLJA1+P2

Cerabar Pressure Transmitter, HART, LCD, Alu.Housing w/Window

Order #: PMP51-AA21JD1PGFRLJA1+P2

Usually ships in 7-10 days

$1,348.00 USD
Add Items to Cart Add to Quote

Endress+Hauser PMP51-F122ID1WGJR1JA2+AAHBPA Endress+Hauser PMP51-F122ID1WGJR1JA2+AAHBPA

Cerabar Pressure Transmitter, FM IS/XP, HART, 6000psi gauge

Order #: PMP51-F122ID1WGJR1JA2+AAHBP

Usually ships in 7-10 days

$1,405.00 USD
Add Items to Cart

Overview :

Product Highlights

  • Accurate measurement of the process value even in the case of changing process temperature
  • Process safety assured with small flush mounted process connections in hygienic applications
  • For process pressure monitoring up to SIL2, certified to IEC 61508 and IEC 61511
  • Modular concept for easy replacement of display or electronics
  • Easy menu-guided commissioning via on-site display, 4 to 20mA with HART, PROFIBUS PA, FOUNDATION Fieldbus
  • Seamless and independent system integration (HART/PA/FF)

Field of Application

Single chamber aluminum or stainless steel (316L) housing.

  • Process connections: Threads, flanges or hygienic connections
  • Process temperature: -40 to +130°C (-40 to +266°F), 150°C (302°F) for 1h
  • Measuring range: -1/0 up to +400bar (-15/0 up to +6,000psi)
  • Accuracy: ±0.15%, "Platinum" ±0.075%
  • International explosion protection certificates, overfill prevention WHG, SIL, hygienic approvals, marine approvals

Specifications :


Continuous/Liquids
Measuring Principle Hydrostatic
Characteristic / Application Smart and reliable pressure transmitter, with piezoresistive measuring cell and metal welded process isolating diaphragm
Supply / Communication 4 ..20mA HART:
11,5...45V DC
Ex ia: 11,5...30V DC
PROFIBUS PA
FOUNDATION Fieldbus
Accuracy 0,15% Platinum 0,075%
Long Term Stability 0,1% of URL/year
Ambient Temperature -40°C...85°C (-40°F...185°F)
Process Temperature -40°C...125°C (-40°F...275°F)
Process Pressure Absolute / Max. Overpressure Limit 600bar (9000psi)
Pressure Measuring Range 1bar...400bar (15psi...6000psi)
Main Wetted Parts 316L
Process Connection Threads
Flanges (DIN, ASME, JIS)
Hygienic connections
Tri-Clamp ISO2852
Max. Measurement Distance 4000m (13.123ft) H2O
Output 4...20 mA HART
PROFIBUS PA
FOUNDATION Fieldbus
Certificates / Approvals ATEX, FM, CSA, CSA C/US, IEC Ex, TIIS, INMETRO, NEPSI
SIL
EN10204-3.1
NACE
CoC ASME-BPE
3A, EHEDG
Marine
Options local display
Application Limits Measuring cell: Metal welded
If pressurized, possibly use differential pressure meas-urement with two pressure transmitters (electronic dp). Observe ratio head pressure : hydrostatic pressure


Pressure
Measuring Principle Hydrostatic
Characteristic Smart and reliable pressure transmitter, with piezoresistive measuring cell and metal welded process isolating diaphragm
Supply Voltage 4...20mA HART
11,5...45V DC (Non Ex):
Ex ia: 11,5...30V DC
PROFIBUS PA:
9...32 V DC (Non Ex)
FOUNDATION Fieldbus:
9...32 V DC (Non Ex)
Reference Accuracy Standard 0,15%
Platinum 0,075%
Long Term Stability Less than 0,1% of URL/year
Less than 0,175% of URL/ 5 years
Process Temperature -40°C...130°C
(-40°F...266°F)
150°C for 1h
(302°F for 1h)
Ambient Temperature -40°C...85°C (-40°F...185°F)
Measuring Cell 400mbar...400bar
(15psi...6000psi)
relative/ absolute
Smallest Calibratable Span 20 mbar (2.9 psi) rel./ abs.
Vacuum Resistance 10 mbar (1.45 psi) abs.
Max. Turn Down 20:1
Max. Overpressure Limit 600bar (9000psi)
Process Connection Thread: G1/2...G2, MNPT1/2...MNPT2
Flange: DN25...DN80, ASME 1 1/2"...4"
Hygienic Tri-Clamp
DIN11851
NEUMO
Varivent N
SMS
DRD
Material Process Membrane 316L, AlloyC, Tantal, Rhodium, Gold
Material Gasket None, measuring cell welded
Fill Fluid Silicone oil, Inert oil
Material Housing Die-cast aluminum, AISI 316L
Output 4...20 mA
4...20 mA HART
PROFIBUS PA
FOUNDATION Fieldbus
Certificates / Approvals ATEX, FM, CSA, CSA C/US, IEC Ex, TIIS, INMETRO, NEPSI
SIL
EN10204-3.1
NACE
3A, EHEDG
CoC ASME-BPE
GL/ ABS/ LR/ BV/ DNV Marine
NSF Drinking water
Options Display
PWIS free

Video :