Skip Navigation Links
Transcat

Hanna Instruments HI2211-02

Basic pH/ORP Benchtop Meter, 230V

Hanna Instruments HI2211-02 
Transcat Order#: HI2211-02
Model: Hanna Instruments HI2211-02
Mfg Part#: HI2211-01
Our Price: $395.00 USD
Qty:    

Availability: Usually ships in 7-10 days

Product Highlights
  • Simple to operate
  • Automatic Temperature Compensation
  • Automatic calibration
  • Calibration expiration reminder
  • ORP range
  • Range pH -2.00 to 16.00 pH
  • Range mV ±399.9 mV; ±2000 mV
  • Range Temperature -20 to 120.0°C
  • Resolution pH 0.01 pH
  • Resolution mV 0.1 mV; 1 mV
  • Resolution Temperature 0.1 °C
  • Accuracy pH ±0.01 pH
  • Accuracy mV ±0.2 mV (±399.9 mV); ±1 mV (±2000 mV)
  • Accuracy Temperature ±0.4 °C (excluding probe error)
  • pH Calibration automatic, 1 or 2 point with 5 memorized buffer values (pH 4.01, 6.86, 7.01, 9.18, 10.01)
  • Temperature Compensation automatic (with HI 7662 probe) or manual from -9.9 to 120 °C
  • pH Electrode HI 1131B, glass-body, single junction, refillable, BNC connector, 1 m cable (included)
  • Temperature Probe HI 7662 with 1 m (3.3') cable (included)
  • Input Impedance 1012 Ohm
  • Power Supply 12 VDC adapter (included)
  • Environment 0 to 50°C (32 to 122°F); RH max 95%
  • Dimensions 235 x 222 x 109 mm (9.2 x 8.7 x 4.3”)
  • Weight 1.3 kg (2.9 lbs.)

 
 
 
Each Unit Includes...
  • HI 1131B pH electrode
  • HI 7662 temperature probe
  • HI 76404N electrode holder
  • HI 70004 pH 4.01 buffer solution sachet
  • HI 70007 pH 7.01 buffer solution sachet
  • HI 7071S electrolyte solution (30 mL)
  • HI 700661 cleaning solution sachet
  • 12 VDC adapter
  • Instructions

 

Product Highlights

  • Simple to operate
  • Automatic Temperature Compensation
  • Automatic calibration
  • Calibration expiration reminder
  • ORP range
  • Range pH -2.00 to 16.00 pH
  • Range mV ±399.9 mV; ±2000 mV
  • Range Temperature -20 to 120.0°C
  • Resolution pH 0.01 pH
  • Resolution mV 0.1 mV; 1 mV
  • Resolution Temperature 0.1 °C
  • Accuracy pH ±0.01 pH
  • Accuracy mV ±0.2 mV (±399.9 mV); ±1 mV (±2000 mV)
  • Accuracy Temperature ±0.4 °C (excluding probe error)
  • pH Calibration automatic, 1 or 2 point with 5 memorized buffer values (pH 4.01, 6.86, 7.01, 9.18, 10.01)
  • Temperature Compensation automatic (with HI 7662 probe) or manual from -9.9 to 120 °C
  • pH Electrode HI 1131B, glass-body, single junction, refillable, BNC connector, 1 m cable (included)
  • Temperature Probe HI 7662 with 1 m (3.3') cable (included)
  • Input Impedance 1012 Ohm
  • Power Supply 12 VDC adapter (included)
  • Environment 0 to 50°C (32 to 122°F); RH max 95%
  • Dimensions 235 x 222 x 109 mm (9.2 x 8.7 x 4.3”)
  • Weight 1.3 kg (2.9 lbs.)


Each Unit Includes

  • HI 1131B pH electrode
  • HI 7662 temperature probe
  • HI 76404N electrode holder
  • HI 70004 pH 4.01 buffer solution sachet
  • HI 70007 pH 7.01 buffer solution sachet
  • HI 7071S electrolyte solution (30 mL)
  • HI 700661 cleaning solution sachet
  • 12 VDC adapter
  • Instructions



HOME   |    PRODUCTS   |    CALIBRATION   |    REPAIR   |    CONTACT   |    INVESTOR RELATIONS   |    CAREERS   |    ABOUT